[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: cleaner wiring solution needed
I used to buy from a contractor supply co. over the phone. Every now and =
then I will see them at Harbor Freight (not very good quality). Try CED =
if you have one in Ballmore (Consoldated Electrical Distributors). Home =
Depot used to have them too. They come in packs of 10 which is really 20 =
bits. They're perfect for those concrete filled steel door frames.
Lemme wrack me peasized brain remember.
"Jackcsg" <nospam@xxxxxxxxxx> wrote in message =
news:SsqdnT0rRdArY9jfRVn-tg@xxxxxxxxxxxxxxx
> Where do you get them? I hand them 1/8" bits out like they're =
hotcakes.
>=20
> "Crash Gordon=AE" <NONE@xxxxxxxx> wrote in message
> news:CZm1e.36$q_1.1699@xxxxxxxxxxxxxxxxxx
> I buy contractor packs of those double-ended 1/8" bits, you ever see =
them? -
> they're tipped at both ends...ya just turn them around and use the =
other
> side...and they're cheap too.
>=20
>=20
> "Jackcsg" <nospam@xxxxxxxxxx> wrote in message
> news:4NydnaHdSr0eZ9jfRVn-gA@xxxxxxxxxxxxxxx
> > "Robert L. Bass" <robertlbass@xxxxxxxxxxx> wrote in message
> > news:5PKdnYUkPOWEftjfRVn-jw@xxxxxxxxxxxxxx
> > > > I only use 1078 contacts for recessed installs...
> > >
> > > That explains it. That 3/4" hole would accomodate 12-gauge if you
> wanted
> > > it. :^)
> > >
> > > > In fact, other than some tuff concrete filled
> > > > doors or a few roll-ups here and there....it's
> > > > the only contact I use...
> > >
> > > I used those on cement filled steel door frames in my old church =
in CT
> > years
> > > ago. It was a royal pain clearing the cement after dulling a new =
hole
> saw
> > > arbor.
> >
> > It's a trade off on the bit. I usually have a nice sharp one to get
> through
> > the steel, then pull out a practically rounded over one for the =
blast out.
> > It's extremely fun with the drill on roto-hammer. I've had a few =
customers
> > ask "what the f**k are you doing!" It's all good....
> >
> > > > I just drill out the Motions and Glassbreaks.
> > > > I've just noticed better results...
> > >
> > > Hey, if it works for you that's all that counts.
> > >
> > > --=20
> > >
> > > Regards,
> > > Robert L Bass
> > >
> > > =
=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=
=3D=3D=3D=3D>
> > > Bass Home Electronics
> > > 2291 Pine View Circle
> > > Sarasota =B7 Florida =B7 34231
> > > 877-722-8900 Sales & Tech Support
> > > http://www.bassburglaralarms.com
> > > =
=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=
=3D=3D=3D=3D>
> > >
> > >
> >
> >
>=20
>=20
>
alt.security.alarms Main Index |
alt.security.alarms Thread Index |
alt.security.alarms Home |
Archives Home