[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: cleaner wiring solution needed



"Robert L. Bass" <robertlbass@xxxxxxxxxxx> wrote in message
news:Jbmdnbj2ePWnL9jfRVn-3A@xxxxxxxxxxxxxx
> > I started using 18 awg wire as a minimum
> > on all my installs. The wire holds up
> > better to those who come behind me, and
> > it holds up better on the installs for
> > pulling.  I run 18/6 to all my keypads for
> > access control.  All in all, I've had much
> > fewer problems, which offsets the cost
> > difference.
>
> True, the cost difference is insignificant compared to hardware and labor.
> But I prefer standard 22/4 for recessed contacts because it's easier to
push
> back in the 3/8" hole.  It's also a pain getting 18/4 into the wire entry
> holes of many glass breaks and motion detectors.
>
> If you're getting better results with 18-gauge that's fine though.
>
I only use 1078 contacts for recessed installs. In fact, other than some
tuff concrete filled doors or a few roll-ups here and there....it's the only
contact I use. I just drill out the Motions and Glassbreaks. I've just
noticed better results...My trucks a little more weighted down though.




alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home