Re: programming an Ademco Vista
By the way, I suggest that your zone summary for that motion detector
should look like this: NOTE: I'm assuming you are using Normally
Closed mode (with NO resistor). Also, I used zone 08 as an example.
In your case whatever zone you're using for the motion would be here.
Also, if it's monitored there should be a 10 under RC, otherwise it
will be 00:
ZN ZT P RC HW : RT
08 04 1 00 NC 1
Also, make sure there isn't some number in *182 or *184. You don't
need to configure any special zones. I know you mentioned it earlier,
and maybe you still have a number floating around in one of these
fields. Make them all zeros.
Let us know how you make out.