[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: programming an Ademco Vista



On Apr 24, 3:31=A0pm, "Crash Gordon" <webmas...@xxxxxxxxxxxxxxxxxxxxx>
wrote:
> cool...have fun!
>
> --
> **Crash Gordon**
>
> <ri...@xxxxxxxxxxxxxx> wrote in message
>
> news:be421883-fb07-41ef-9a11-486d0d26bceb@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
>
>
>
> > On Apr 23, 8:53 pm, "Crash Gordon" <webmas...@xxxxxxxxxxxxxxxxxxxxx>
> > wrote:
> >> *182 is for custom zones
> >> just use *56 area and the zone types I gave or any of the standard ones=

> >> on
> >> page 12
>
> >> --
> >> **Crash Gordon**
>
> >> <ri...@xxxxxxxxxxxxxx> wrote in message
>
> >>news:93867c25-3c02-49f0-bb59-cdcd03d85e62@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx=

>
> >> > On Apr 22, 10:08 pm, "Crash Gordon" <webmas...@xxxxxxxxxxxxxxxxxxxxx>=

> >> > wrote:
> >> >> I hardly ever use customizable zone types.
> >> >> Is there a reason you don't want to use normal zone types?
>
> >> >> 01 Entry/Exit #1 - delayed doors
> >> >> 03 Perimeter - instant doors/windows
> >> >> 04 Interior Follower - interior device (pir) that follows entry dela=
y
> >> >> if
> >> >> delay zones are faulted first... but instant in other cases
>
> >> >> --
> >> >> **Crash Gordon**
>
> >> >> <ri...@xxxxxxxxxxxxxx> wrote in message
>
> >> >>news:d3ddc02b-3c86-4da5-b671-44da1576e835@xxxxxxxxxxxxxxxxxxxxxxxxxxx=
m...
>
> >> >> > Has anyone programmed an Ademco Vista 20P? =A0Whats a typical entr=
y
> >> >> > for
> >> >> > *182:
>
> >> >> > 1) =A0door switches
> >> >> > 2) =A0IR motion
>
> >> >> > thanks
>
> >> > Im after just a vanilla setup, the manual implies that *182 is
> >> > required so thats what I was trying to get working.
> >> > Sounds like that is not right so Im open. =A0Is *56 the right field?
>
> > after *97 and *56, the Vista finally came up and showed some life.
> > testing is next
>
> > Thanks!!!- Hide quoted text -
>
> - Show quoted text -



Something is still not right.  The system is up, will arm and both
pads are talking to the main box yet none of the sensors trip the
alarm.
The motion sensor is getting power and is functioning.  The door
switch worked on the old main box.  I tried "test" and "chime" mod and
they do nothing.  There are no error mesages or faults.

The old alarm had each connection wired with a series resistor.  This
manual doesnt really say if the resister should be connected

door    -------------------------- HI
switch ---------------/\/\/\/\-----LO

IR       -------------------------- HI
sensor ---------------/\/\/\/\-----LO
pwr    ---------------------------aux +
gnd    ---------------------------aux -

Is this correct?  any suggestion on what to check?





alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home