[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Ademco Vista 15P PGM output for armed condition



On Nov 24, 2:05=A0pm, mleuck <m.le...@xxxxxxxxx> wrote:
> On Nov 24, 12:02=A0pm, Jim Rojas <jro...@xxxxxxxxxxxx> wrote:
>
>
>
> > Robert L Bass wrote:
> > > "Jim Rojas" wrote:
>
> > >> Tower Security wrote:
> > >>>> ...you should be able to do it
> > >>>> exactly the same way as adding an LED that is on when armed, just
> > >>>> powering a relay to hold the circuit open instead of an LED.
>
> > >>> Precisely...which still means programming sections 79 and 80 correc=
tly
> > >>> and I'm hoping that someone has done this previously and can provid=
e
> > >>> some assistance...
>
> > >>> Doing this on a DSC is as simple as programming a 17 in section
> > >>> 009...surely someone can translate this into Ademcobabble?!?...
>
> > >> I don't even know if you can do it through the keypad on an Ademco
> > >> Vista 15P...I usually do it through the software. You select a relay
> > >> and output and choose which zones trigger the output, and for whatev=
er
> > >> condition or reason. DSC is very simplistic. Ademco gets into more
> > >> details and options when it comes to relay outputs.
>
> > > I hate programming Hoineywell panels, but here's the routine. I *thin=
k*
> > > this is correct. :^)
>
> > > Enter program mode by powering down then back up
> > > and pressing the *+# simultaneously within 50 seconds
> > > of power up, or enter the Installer code:
> > > (4112) + 8 + 0 + 0
>
> > > Screen displays:
> > > "INSTALLER CODE 20"
> > > Press *80
>
> > > Screen displays:
> > > "Output Funct #" 01
> > > Press 01*
>
> > > Screen displays:
> > > "01 A E Trig
> > > ?00 0 0 - ZL =3D00"
> > > Press *
>
> > > Screen Displays:
> > > "01 Activated By: Delete 0"
> > > Press 2
>
> > > Screen will display:
> > > "01 Enter Zone Type"
> > > Press 21 =3D Arming-AWAY
>
> > > After this:
> > > Press *
> > > Press *
>
> > > Screen displays:
> > > "Output action"
> > > Press 2 =3D Close and Stay Closed
>
> > > Screen displays:
> > > "Enter Output No."
> > > Press 17 =3D Trigger 1
> > > or
> > > 18 =3D Trigger 2
>
> > > Screen displays summery:
> > > "01 A E Trig
> > > ?00 0 0 - ZL =3D00"
> > > Press *
>
> > > Screen displays "Output Funct #"
> > > Press 00 to quit
>
> > > Hope that helps.
>
> > Like I said...better off using the software. :)
>
> > Jim Rojas
>
> Not really, takes 2 minutes at the keypad

I agree, if he doesn't have software already set up he'll spend more
time futzing around than if he just banged it out at the keypad.

Reminds me of a guy I worked with. He would walk all the way across a
building and back to the the van to get a battery screw gun instead of
using the manual screwdriver in his toolbag, just to remove 1 or 2
screws.  Used to crack me up.

The reason I mentioned the LED is most ademco panel instruction
manuals have simplified instructions for setting up a keyswitch with
an armed LED, or they used to anyway, I think.