[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: Ademco Vista 15P PGM output for armed condition
On Nov 24, 12:02=A0pm, Jim Rojas <jro...@xxxxxxxxxxxx> wrote:
> Robert L Bass wrote:
> > "Jim Rojas" wrote:
>
> >> Tower Security wrote:
> >>>> ...you should be able to do it
> >>>> exactly the same way as adding an LED that is on when armed, just
> >>>> powering a relay to hold the circuit open instead of an LED.
>
> >>> Precisely...which still means programming sections 79 and 80 correctl=
y
> >>> and I'm hoping that someone has done this previously and can provide
> >>> some assistance...
>
> >>> Doing this on a DSC is as simple as programming a 17 in section
> >>> 009...surely someone can translate this into Ademcobabble?!?...
>
> >> I don't even know if you can do it through the keypad on an Ademco
> >> Vista 15P...I usually do it through the software. You select a relay
> >> and output and choose which zones trigger the output, and for whatever
> >> condition or reason. DSC is very simplistic. Ademco gets into more
> >> details and options when it comes to relay outputs.
>
> > I hate programming Hoineywell panels, but here's the routine. I *think*
> > this is correct. :^)
>
> > Enter program mode by powering down then back up
> > and pressing the *+# simultaneously within 50 seconds
> > of power up, or enter the Installer code:
> > (4112) + 8 + 0 + 0
>
> > Screen displays:
> > "INSTALLER CODE 20"
> > Press *80
>
> > Screen displays:
> > "Output Funct #" 01
> > Press 01*
>
> > Screen displays:
> > "01 A E Trig
> > ?00 0 0 - ZL =3D00"
> > Press *
>
> > Screen Displays:
> > "01 Activated By: Delete 0"
> > Press 2
>
> > Screen will display:
> > "01 Enter Zone Type"
> > Press 21 =3D Arming-AWAY
>
> > After this:
> > Press *
> > Press *
>
> > Screen displays:
> > "Output action"
> > Press 2 =3D Close and Stay Closed
>
> > Screen displays:
> > "Enter Output No."
> > Press 17 =3D Trigger 1
> > or
> > 18 =3D Trigger 2
>
> > Screen displays summery:
> > "01 A E Trig
> > ?00 0 0 - ZL =3D00"
> > Press *
>
> > Screen displays "Output Funct #"
> > Press 00 to quit
>
> > Hope that helps.
>
> Like I said...better off using the software. :)
>
> Jim Rojas
Not really, takes 2 minutes at the keypad
alt.security.alarms Main Index |
alt.security.alarms Thread Index |
alt.security.alarms Home |
Archives Home