[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Programming problem on Vista 20P



That's a thought.

I'm still thinking the mirror and the recievers being mounted so low is =
a contributor to problem...except  he claims this is a recent problem. I =
don't think its a programming problem or they wouldn't work at all...and =
I've replaced all batts...system, points, keyfobs. I hate to even =
mention the "m" word.




"Robert L. Bass" <robertlbass@xxxxxxxxxxx> wrote in message =
news:auadnfyxPb-ZPvLfRVn-pA@xxxxxxxxxxxxxx
> > This was a takeover from a 3letter company. I've personally only =
installed=20
> > a handful of 5804bd/tm's. I'm not a big fan of devices that disarm a =

> > system without a code entry.
>=20
> > But, anyway...the orig. installing co. put the box/5800tm/5881/ all =
down=20
> > on the floor in a closet with mirrored doors. I think I spoke about =
this=20
> > before...but it's happening on and off. Sometimes it works=20
> > fine,,,sometimes it's slow...the other day it wouldn't disarm when =
they=20
> > accidently set it off, they had to enter their code at the keypad.
>=20
> > It's an old Vista 10se ver. 12. Owners say its 10 years old. =
Everything=20
> > works fine except this intermittant behavior of the 5804bd (actually =
they=20
> > have two of them).
>=20
> Hi Crash,
>=20
> Not sure if this is it but on some older panels I've seen a problem=20
> responding to RF remotes when the siren was active.  It turned out to =
be a=20
> power problem.  The siren would draw so much current that the voltage=20
> available at the receiver was dropping.  You can check to see if this =
is=20
> happening by testing the voltage at the receiver with and without =
siren.=20
> It's a long shot but it's easy enough to check.  If that does turn out =
to be=20
> the problem you can offload the siren(s) from the panel power supply =
with a=20
> relay wired directly to the battery.
>=20
> Frank would remind you if I didn't to run the power through an inline =
fuse.=20
> :^)
>=20
> --=20
>=20
> Regards,
> Robert L Bass
>=20
> =
=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=
=3D=3D=3D=3D>
> Bass Home Electronics
> 2291 Pine View Circle
> Sarasota =B7 Florida =B7 34231
> 877-722-8900 Sales & Tech Support
> http://www.bassburglaralarms.com
> =
=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=
=3D=3D=3D=3D>=20
>=20
>


alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home