On 11/9/2011 10:30 PM, Jim wrote:
> On Nov 9, 6:08 pm, JoeRaisin<joeraisin2...@xxxxxxxxx>  wrote:
>> On 11/8/2011 10:07 PM, Jim wrote:
>>
>>
>>
>>
>>
>>> On Nov 8, 6:19 pm, JoeRaisin<joeraisin2...@xxxxxxxxx>    wrote:
>>>> On 11/8/2011 7:10 AM, JoeRaisin wrote:
>>
>>>>> On 11/7/2011 11:27 PM, Jim wrote:
>>>>>> On Nov 4, 5:15 am, JoeRaisin<joeraisin2...@xxxxxxxxx>    wrote:
>>>>>>> On 11/3/2011 9:53 PM, Jim wrote:
>>
>>>>>>>> On Nov 3, 6:46 pm, JoeRaisin<joeraisin2...@xxxxxxxxx>    wrote:
>>>>>>>>> On 11/3/2011 2:27 AM, Robosama wrote:
>>
>>>>>>>>>> Like a W3-ADT smoke is really a 5808 rf smoke...dunno why they
>>>>>>>>>> think we
>>>>>>>>>> are incapable of figuring out this stuff.
>>
>>>>>>>>>> Still wish I had the ADT personality files for Compass though.
>>
>>>>>>>>>> :-)
>>
>>>>>>>>>> "JoeRaisin"<joeraisin2...@xxxxxxxxx>    wrote in message
>>>>>>>>>> news:j7vq9g$csj$1@xxxxxxxxxxxxxxxx
>>>>>>>>>>> On 10/22/2011 5:17 PM, mleuck wrote:
>>>>>>>>>>>> On Oct 21, 3:23 am, G. Morgan<G_Mor...@xxxxxxxx>    wrote:
>>>>>>>>>>>>> mleuck Wrote:
>>
>>>>>>>>>>>>>> On Oct 20, 7:14 am, G. Morgan<G_Mor...@xxxxxxxx>    wrote:
>>>>>>>>>>>>>>> Jim Rojas Wrote:
>>
>>>>>>>>>>>>>>>> ADT has their own variation of CID codes in these panels. It
>>>>>>>>>>>>>>>> sounds like
>>>>>>>>>>>>>>>> a bug.
>>
>>>>>>>>>>>>>>> And who are they to redefine CID for proprietary panels? What
>>>>>>>>>>>>>>> a joke.
>>
>>>>>>>>>>>>>> It would be a joke if they did it which they don't
>>
>>>>>>>>>>>>> Not the last time I looked. I know they have "extended" codes for
>>>>>>>>>>>>> proprietary use on new-gen panels, but not on a SW/3000 over a
>>>>>>>>>>>>> dozen
>>>>>>>>>>>>> years old.
>>
>>>>>>>>>>>> Extended codes yes but redefining old codes no, besides the 3000
>>>>>>>>>>>> is a
>>>>>>>>>>>> Vista-20P and one can go into the configurable zone section and
>>>>>>>>>>>> reprogram zones to send anything
>>
>>>>>>>>>>> This one wasn't programmed as a configurable zone - simple
>>>>>>>>>>> entry/exit.
>>
>>>>>>>>>>> Mark, been meaning to ask you something but I'm not sure if I
>>>>>>>>>>> remember
>>>>>>>>>>> something right. I think I have seen posts in the past indicating
>>>>>>>>>>> you
>>>>>>>>>>> may have some knowledge of ADT systems.
>>
>>>>>>>>>>> I can't figure out what point type a motion detector should be on a
>>>>>>>>>>> Focus panel. There is no "interior follower" or anything that seems
>>>>>>>>>>> like one. The ADT techs I have asked say they just make them either
>>>>>>>>>>> delayed or instant perimeter types based on where they are.
>>
>>>>>>>>>>> Why do they have to rename stuff?
>>
>>>>>>>>> Just installed a focus panel with a new zone added - "Movable Instant
>>>>>>>>> PIR". Unless of course the motion covers an entry path, then you have
>>>>>>>>> to make it "Movable Delay".
>>
>>>>>>>>> What was wrong with the good old, "Interior Follower"?-
>>
>>>>>>>> I can't imagine what that might indicate ....."movable instant PIR" ?
>>
>>>>>>>> Is it just a follower zone or something different?
>>
>>>>>>> Took me a while to figure it out.
>>
>>>>>>> If a zone responds the same way whether the system is armed or not, it
>>>>>>> is "Fixed". If it responds differently it is "movable".
>>
>>>>>>> A 24 hr point, even if it is just a trouble by day, is "fixed". A
>>>>>>> regular burg zone that doesn't alarm when the system is disarmed, is
>>>>>>> "movable". For some reason adt did away with the follower zone on the
>>>>>>> Focus panel. Motions either have a delay, or they don't.
>>
>>>>>>> Quite a few of the adt techs say they program everything with a delay.-
>>
>>>>>> I just came across a system a few months ago that had every zone a
>>>>>> delay zone. I forget who's it was. Amazing what some of these
>>>>>> installation companys do. But I've got to put some of the blame on the
>>>>>> end user too. I'f they'd only do their home work ... shit like that
>>>>>> wouldn't happen.
>>
>>>>>> I think that it's very convenient that ADT uses the Focus panel. When
>>>>>> the disatisfied end user is asked what ADT did to them .... all they
>>>>>> end user has to say is ...... Focus!
>>
>>>>> Heh-heh
>>
>>>>> What do they do to us subcontractors? ... Focus!
>>
>>>>> The Focus panel isn't all bad though. I do like the ATM style keypad,
>>>>> lots convenient features from a service perspective. Some PITA issues
>>>>> too - Quite a few things can only be done through hex programming.
>>
>>>>> I've been putting in quite a few Vista-128's for them recently. Usually
>>>>> on hybrid systems but occasionally (like the job I'm on now) It's to
>>>>> monitor a sprinkler riser. One smoke, one horn (external) and where is
>>>>> the pull station you might ask... If you did, you would be told that we
>>>>> are going to wait for the AHJ to tell us to put it in - which most don't.
>>
>>>> LOL - Fire Marshall was on site today to look at the sprinklers.  Three
>>>> guesses as to what he is requiring to be added to the job?  First two
>>>> guesses don't count...-
>>
>>> 1 A pull station
>>> 2 A pull station
>>> 3  A heat detector!
>>
>> LOL - Boss says I don't pull a foot of wire until adt gives him a job
>> number - and I haven't gotten one as of this afternoon.
>>
>> We keep getting screwed on those "get it done, paperwork to follow"
>> deals.  Boss says, "No more free work..."-
>
> Yeah I'm going through that right now with an electrician I met on a
> job. He was working on another job and the builder asked him if he
> could install and alarm. He couldn't so he asked me if I wanted to do
> it to help him out. I said sure and he said he'd pay me and he'd bill
> the builder. ( I figured he's going to make a few bucks on the
> job ..... Ok with me since I quoted my regular price.)  I pre wired
> the house in one day, took me 12 hours all by my self, worked till
> 9:00 PM at nite because they were insulating in the morning. It's been
> 4 weeks now and still no check.
>
> You'd think that after all these years I'd be smart enough to not give
> a damn and not try to help someone out.
>
> However, I've left my self a couple off ways to access the house. I'll
> keep an eye on the progress and if ultimately I don't get the check, I
> can get in to cut all the wires off at all the openings and at the
> panel.
>
> Don't fuck with Jim.

So, yesterday morning I'm in the ADT office checking to see if they have
the rest of my parts (another issue - don't get me started).

I ask our contact if he's got a job for that pull station so I can get
started on it.  He asks why it isn't done, I tell him what the boss told
me.  I also remind him that the customer was granted temp occupancy
based on the promise of a finished fire alarm by the 11th.

Two hours later, the salesman shows up on the job with a pull station
and a rider for the customer to sign.

I know where it's going and that I'm going to have to pull up a sheet of
plywood from the mezzanine floor to get it.  One nearly sprained finger
later I'm feeling around for the top plate under all the blown in
insulation between the 2' deep scissor trusses.  Oh, there it is, with a
10 inch hvac supply duct running along on top of it.

Gotta admit to giving in to a little frustration.  It had enough play
that I only had to bend it a little bit and after I ran the wire I was
able to get it 'mostly' round again...

Oh yeah, customer only has one potts line and got permission from the
ahj to use a T1 - voip line for the back up.  According the T1 provider
there is no way to get line seizure.  Customer has to get an "Analog
Terminal Adapter" and dedicate one of their voip numbers to the alarm
panel - and they are recommending that we do not do it.  But, apparently
we are...

System is done, tested and working except for the trouble on dialer 2
but nothing can be done about that until the customer has the gear.

Now if I can finish up the card access and CCTV out there today,
everyone will be happy...