Re: Trying to wrap my head around it
On 11/3/2011 9:53 PM, Jim wrote:
> On Nov 3, 6:46 pm, JoeRaisin<joeraisin2...@xxxxxxxxx> wrote:
>> On 11/3/2011 2:27 AM, Robosama wrote:
>>
>>
>>
>>
>>
>>> Like a W3-ADT smoke is really a 5808 rf smoke...dunno why they think we
>>> are incapable of figuring out this stuff.
>>
>>> Still wish I had the ADT personality files for Compass though.
>>
>>> :-)
>>
>>> "JoeRaisin"<joeraisin2...@xxxxxxxxx> wrote in message
>>> news:j7vq9g$csj$1@xxxxxxxxxxxxxxxx
>>>> On 10/22/2011 5:17 PM, mleuck wrote:
>>>>> On Oct 21, 3:23 am, G. Morgan<G_Mor...@xxxxxxxx> wrote:
>>>>>> mleuck Wrote:
>>
>>>>>>> On Oct 20, 7:14 am, G. Morgan<G_Mor...@xxxxxxxx> wrote:
>>>>>>>> Jim Rojas Wrote:
>>
>>>>>>>>> ADT has their own variation of CID codes in these panels. It
>>>>>>>>> sounds like
>>>>>>>>> a bug.
>>
>>>>>>>> And who are they to redefine CID for proprietary panels? What a joke.
>>
>>>>>>> It would be a joke if they did it which they don't
>>
>>>>>> Not the last time I looked. I know they have "extended" codes for
>>>>>> proprietary use on new-gen panels, but not on a SW/3000 over a dozen
>>>>>> years old.
>>
>>>>> Extended codes yes but redefining old codes no, besides the 3000 is a
>>>>> Vista-20P and one can go into the configurable zone section and
>>>>> reprogram zones to send anything
>>
>>>> This one wasn't programmed as a configurable zone - simple entry/exit.
>>
>>>> Mark, been meaning to ask you something but I'm not sure if I remember
>>>> something right. I think I have seen posts in the past indicating you
>>>> may have some knowledge of ADT systems.
>>
>>>> I can't figure out what point type a motion detector should be on a
>>>> Focus panel. There is no "interior follower" or anything that seems
>>>> like one. The ADT techs I have asked say they just make them either
>>>> delayed or instant perimeter types based on where they are.
>>
>>>> Why do they have to rename stuff?
>>
>> Just installed a focus panel with a new zone added - "Movable Instant
>> PIR". Unless of course the motion covers an entry path, then you have
>> to make it "Movable Delay".
>>
>> What was wrong with the good old, "Interior Follower"?-
>
> I can't imagine what that might indicate ....."movable instant PIR" ?
>
> Is it just a follower zone or something different?
Took me a while to figure it out.
If a zone responds the same way whether the system is armed or not, it
is "Fixed". If it responds differently it is "movable".
A 24 hr point, even if it is just a trouble by day, is "fixed". A
regular burg zone that doesn't alarm when the system is disarmed, is
"movable". For some reason adt did away with the follower zone on the
Focus panel. Motions either have a delay, or they don't.
Quite a few of the adt techs say they program everything with a delay.