[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Ademco Vista 15P PGM output for armed condition



On Nov 24, 9:11=A0pm, James B <den...@xxxxxxxxx> wrote:
> On Nov 24, 3:36=A0am, "Robert L Bass" <Sa...@xxxxxxxxxxxxxxxxxxxxx>
> wrote:
>
>
>
> > "Jim Rojas" wrote:
>
> > > Tower Security wrote:
> > >>> ...you should be able to do it
> > >>> exactly the same way as adding an LED that is on when armed, just
> > >>> powering a relay to hold the circuit open instead of an LED.
>
> > >> Precisely...which still means programming sections 79 and 80 correct=
ly
> > >> and I'm hoping that someone has done this previously and can provide
> > >> some assistance...
>
> > >> Doing this on a DSC is as simple as programming a 17 in section
> > >> 009...surely someone can translate this into Ademcobabble?!?...
>
> > > I don't even know if you can do it through the keypad on an Ademco Vi=
sta
> > > 15P...I usually do it through the software. You select a relay and ou=
tput and
> > > choose which zones trigger the output, and for whatever condition or =
reason.
> > > DSC is very simplistic. Ademco gets into more details and options whe=
n it
> > > comes to relay outputs.
>
> > I hate programming Hoineywell panels, but here's the routine. =A0I *thi=
nk* this is
> > correct. =A0:^)
>
> > Enter program mode by powering down then back up
> > and pressing the *+# simultaneously within 50 seconds
> > of power up, or enter the Installer code:
> > (4112) + 8 + 0 + 0
>
> > Screen displays:
> > =A0 =A0 =A0"INSTALLER CODE 20"
> > =A0 =A0 =A0Press *80
>
> > Screen displays:
> > =A0 =A0 =A0"Output Funct #" 01
> > =A0 =A0 =A0Press 01*
>
> > Screen displays:
> > =A0 =A0 =A0"01 A E Trig
> > =A0 =A0 =A0?00 0 0 - ZL =3D00"
> > =A0 =A0 =A0Press *
>
> > Screen Displays:
> > =A0 =A0 =A0"01 Activated By: Delete 0"
> > =A0 =A0 =A0Press 2
>
> > Screen will display:
> > =A0 =A0 =A0"01 Enter Zone Type"
> > =A0 =A0 =A0Press 21 =3D Arming-AWAY
>
> > After this:
> > =A0 =A0 =A0Press *
> > =A0 =A0 =A0Press *
>
> > Screen displays:
> > =A0 =A0 =A0"Output action"
> > =A0 =A0 =A0Press 2 =3D Close and Stay Closed
>
> > Screen displays:
> > =A0 =A0 =A0"Enter Output No."
> > =A0 =A0 =A0Press 17 =3D Trigger 1
> > =A0or
> > =A0 =A0 =A018 =3D Trigger 2
>
> > Screen displays summery:
> > =A0 =A0 =A0"01 A E Trig
> > =A0 =A0 =A0?00 0 0 - ZL =3D00"
> > =A0 =A0 =A0Press *
>
> > Screen displays "Output Funct #"
> > =A0 =A0 =A0Press 00 to quit
>
> > Hope that helps.
>
> > --
>
> > Regards,
> > Robert L Bass
>
> Robert,
>
> I think you will need to program a stop event as well, so the relay
> will turn off on disarming.
>
> JAmes

Shhhh Robert thinks he can keypad program


alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home