[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Commercial Burg



"ABLE1" <royboynospam@xxxxxxxxxxxxx> wrote in message
news:fex2p.643016$De6.340709@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
>> But I am still looking for the answer to this question, anybody??.
>>
>> Is there anything special with central station requirements such as 24
>> hour
>> test, Supervised Openings/Closings, or anything that would put this over
>> the
>> top of normal??
>>
>> TIA
>>
>> Les
>
> Nothing special on central end that I have seen unless insurance
> company requires it for open close  at minimum a weekly test
> must report  ac loss,   bypass , and troubles  up/ down load must be
> shut off
>  look at program sheet  it will give specific  UL requirements how
> particular settings must be.
> as to what must be reported.
>
>
> Nick,
>
> Again Thanks!!!
>
> Les
>
I would spec the Cell backup as a Honeywell GSMHS, check it out here
http://www.security.honeywell.com/hsc/products/alarm/re/gsm/298410.html ...
The GSMHS has a 200 second Supervision window and is "High Security" (a.k.a.
UL AA) rated...