[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: GEMINI P3200 KEYPAD MESSAGE



=CE=A4=CE=B7 =CE=9A=CF=85=CF=81=CE=B9=CE=B1=CE=BA=CE=AE, 9 =CE=A3=CE=B5=CF=
=80=CF=84=CE=B5=CE=BC=CE=B2=CF=81=CE=AF=CE=BF=CF=85 2012 2:16:15 =CE=BC.=CE=
=BC. UTC+3, =CE=BF =CF=87=CF=81=CE=AE=CF=83=CF=84=CE=B7=CF=82 Frank Kurz =
=CE=AD=CE=B3=CF=81=CE=B1=CF=88=CE=B5:
> On 08/09/2012 10:07 PM, proguard wrote:
>=20
> > On 9 =CE=BF=CE=8F=C2=BD=CE=BF=CE=8F=C2=BD=CE=BF=CE=8F=C2=BD=CE=BF=CE=8F=
=C2=BD, 02:33, G. Morgan <sealte...@xxxxxxxxxxxxxxxxx> wrote:
>=20
> >> proguard...@xxxxxxxxx Wrote:
>=20
> >>
>=20
> >>> I get "enter your code to access area" at GEM-DXRP1 keypad connecting=
 to a Gemini P3200. Even master security code want work. Any idea?
>=20
> >>> Thank you!
>=20
> >>
>=20
> >> If you are trying to get into programming, is it KP #1 ?  Programming
>=20
> >> has to be done on that one.
>=20
> >>
>=20
> >> Master code wont disarm IIRC if that's what you're trying to do.
>=20
> >>
>=20
> >> If the system was working and you just came to service, power-cycle it
>=20
> >> first - that fixes everything on those POS panels. <g>
>=20
> >>
>=20
> >> What *are* you trying to do?
>=20
> >
>=20
> > I made a cold start to the panel and after that i made doownload.
>=20
> > Everything was ok.
>=20
> > I was downloading the panel which was in disarm mode and after ending
>=20
> > download this message came up.
>=20
> > I took the panel on the bench in order to find out what happens.
>=20
> > The keypad is in address 01. Of course i power cycle it but after the
>=20
> > panel boot up this msg came up:
>=20
> > "Enter our code to access area" I used master security code, dealer
>=20
> > code, user code 1, user code 2, but still the same.
>=20
> > "Invalid access code, try again" It's the first time i saw this msg...
>=20
> >
>=20
>=20
>=20
> I'm not all that familiar with the Napco products, but it sounds to me=20
>=20
> like you've programmed the keypad as a global partition and it's not=20
>=20
> actually "parked" in the one you want to arm.  Try entering partition 1=
=20
>=20
> from the keypad and then it should work normally.  When you download it=
=20
>=20
> again (as I'm sure you will), try assigning it to partition 1 and I=20
>=20
> think you'll avoid getting this message.
>=20
>=20
>=20
>=20
>=20
> --=20
>=20
> Fire Protection Technicians Network
>=20
> www.firetechs.net

Its the most strange situation. The panel denies to answer the incoming cal=
l for dl and always get the message "enter your code to access area" !!!
i cannot get into programming even with master security code!


alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home