[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: 4110XM wiring
Rule of thumb if you can't program user code 8 it's the older model
"Crash Gordon" <webmaster@xxxxxxxxxxxxxxxxxxxxx> wrote in message
news:4551499a$0$3567$815e3792@xxxxxxxxxxxxxxxxx
> Yah I didn't even remember it being there on the last one I serviced not
too
> long ago.. so I looked in my tech files and it was there but probably a
> later rev.
>
>
> "Mark Leuck" <m..leuck@xxxxxxxxxxx> wrote in message
> news:ZICdnTgd8fCovczYnZ2dnUVZ_uKdnZ2d@xxxxxxxxxxxxxx
> | Depending on the age of his 4110XM that feature may not exist, they
added
> it
> | later after a few revisions (I think v5 and above)
> |
> | "Crash Gordon" <webmaster@xxxxxxxxxxxxxxxxxxxxx> wrote in message
> | news:455093a1$0$10301$815e3792@xxxxxxxxxxxxxxxxx
> | > Change address 27 to a 0 instead of 1
> | >
> | > Although the audible exit feature is handy in some households....loopy
> | wife
> | > with tons of kids, nice to know you're running out of time to exit.
> | >
> | >
> | >
> | >
> | > "Spladge" <Spladge@xxxxxxxxxxx> wrote in message
> | > news:1162777832.592428.14840@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
> | > |
> | > | Frank, thanks a lot for the help. I connected everything like you
said
> | > | and got rid of my error code. It all looked familiar when I hooked
it
> | > | up. I was all ready to send away for my rocket scientist certificate
> | > | when I realized I have another problem. The display now shows only
AC
> | > | and Ready, as it should. But when I go to armed (away with delay)
> mode,
> | > | the beeper continues to beep although the "armed" indicator light
> comes
> | > | on. It probably beeps once a second. Book says it should beep twice
> and
> | > | then stop. I haven't done any more on it since I noted this. I
decided
> | > | to give it a rest and watch the race. Any clues? Sorry to keep
> | > | bothering you. Thanks
> | > |
> | > |
> | > |
> | > |
> | > | Frank Olson wrote:
> | > | > Frank Olson wrote:
> | > | >
> | > | >
> | > | > PS... "Gree" = "Green". :-)
> | > |
> | >
> | >
> |
> |
>
>