[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Programming Power632 for ContactID reporting



oups!!!

lets check in the manual........



Contact ID

Contact ID is a specialized format that will communicate information

using tones rather than pulses. This format allows more

information to be sent faster than other formats. For example,

in addition to reporting an alarm in zone one, the Contact ID

format will also report the type of alarm, such as an Entry/Exit

alarm.

If the Contact ID uses Programmed Reporting Codes

option is enabled, a two digit number from Appendix A must

be entered in programming sections [320] to [353] for each

event to be transmitted. The two digit number determines the

type of alarm. The panel will automatically generate all other

information, including the zone number.

If the Contact ID uses Automatic Reporting Codes option is

enabled, the panel will operate as follows:

1. If an event's reporting code is programmed as [00], the

panel will not attempt to call the central station.

2. If the reporting code for an event is programmed as anything

from [01] to [FF], the panel will automatically generate

the zone or access code number. See Appendix A for a

list of the codes which will be transmitted.

NOTE:If the Automatic Contact ID option is selected, the panel

will automatically generate all zone and access code numbers,

eliminating the need to program these items.

If the Contact ID uses Programmed Reporting Codes

option is enabled, the panel will operate as follows:

1. If an event's reporting code is programmed as [00] or [FF],

the panel will not attempt to call central station.

2. If the reporting code for an event is programmed as anything

from [01] to [FE], the panel will send the programmed

reporting code.

Additional Notes on Contact ID

1. Account numbers must be four digits.

2. All reporting codes must be two digits.

3. Substitute the HEX digit 'A' for the '0'.

4. To prevent the panel from reporting an event, the reporting

code should be programmed as [00].

Please refer to Appendix A: "Reporting Codes"for a list of

Contact ID Identifiers.

Contact ID Uses Programmed/Automatic Codes . . [381]: [7]



Sorry for the wrong info... ;-)



and sorry Mark..





"alarman" <alarman2000@xxxxxxxxx> a écrit dans le message de news:
SxLDf.24336$jR.2839@xxxxxxxxxxxxx
> "petem" <petem001@xxxxxxxxx> wrote in message
> news:1vIDf.41764$rX.374879@xxxxxxxxxxxxxxxxxxxxxx
>> there is no auto cid in power 832,in power 864 yes..
>
> It's a 1555 (Power 632) Not 832.
> js
>
>