[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: DSC 5020? 5200 power supply needed?
A.J. wrote:
> He is talking about the PC5204. If you are only interested in more constant
> power for the system, the PC5200 will work for you. With the PC5204, it has
> 4 programmable open collector outputs in addition to the 3A power supply.
Got it. I think the PC5204 is what I need. Use the output 1 of the 5204
for the exterior siren output (1.2A max), PC5200 bell output for the
interior siren (480mA), split the aux power between the PC5200 and
PC5204 and put the strobe ( 210mA) on one of the programmed outputs set
for latched system event.
So, I'll need the 5204, transformer, and battery. Is it possible to use
just one larger transformer? Also, does the 5204 come with a CAN or
just the board?
-jr
alt.security.alarms Main Index |
alt.security.alarms Thread Index |
alt.security.alarms Home |
Archives Home