[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: DSC 5020? 5200 power supply needed?



He is talking about the PC5204. If you are only interested in more constant
power for the system, the PC5200 will work for you. With the PC5204, it has
4 programmable open collector outputs in addition to the 3A power supply.


"James Russo" <jr@xxxxxxxxxxxxxxxx> wrote in message
news:gDOKf.36757$g47.2363@xxxxxxxxxxxxxxxxxxxxxxxxxx

> Ok. I'm confused. The PC5200 seems to just have terminals for the
> keybus, tamper, AC input and AUX output. So, I could split the aux
> devices on the PC5020 (864)'s AUX and the PC5200 AUX but then that still
> leaves the real problem which is the siren circuit. Would you use a
> relay to switch the source power for the siren circuit from the 5200
> power supply? Even with that I'd be over the maximum 1A current on the
> 5200. I really don't want to have to add two of these things.
>
> Thanks,
>
> -jr




alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home