[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: DSC 5020? 5200 power supply needed?
You will have to buy the can and transformer seperately. Just connect all
the keypads/expanders to the PC5020 and connect all other devices to the
PC5204, including the interior siren and the strobe.
Not a good idea to use one single larger transforner to power both system..
<james.russo@xxxxxxxxx> wrote in message
news:1140575816.445665.47440@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
>
> Got it. I think the PC5204 is what I need. Use the output 1 of the 5204
> for the exterior siren output (1.2A max), PC5200 bell output for the
> interior siren (480mA), split the aux power between the PC5200 and
> PC5204 and put the strobe ( 210mA) on one of the programmed outputs set
> for latched system event.
>
> So, I'll need the 5204, transformer, and battery. Is it possible to use
> just one larger transformer? Also, does the 5204 come with a CAN or
> just the board?
>
> -jr
>