[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: How to reset service light on CADDX NX-6?



Thanks Allan. That worked like a charm.

Hopefully this won't happen a lot. We have lived here about 5 months and
this was the first occurrence - due to a lengthy power outage we had.


"Allan Waghalter" <awaghalter@xxxxxxxxxxx> wrote in message
news:LteZe.1194$4u4.317@xxxxxxxxxxxxxxxxxxxxxxxxxxxxx
> You can't clear the "Fail to Communicate" without sending a  good
> communication to a central station.  However, you can power down and then
> power back up.... (Remove Battery wire, then remove one side of the AC to
> power down.  To Power up, Connect the AC power first, then the battery).
> This will clear the problem until it attempts to send another
> communication. Then you will have to repeat the above procedure.
>
>
> "Bruce" <bmwhitetxNOSPAM@xxxxxxxxx> wrote in message
> news:YeednYXkDdUqx6jeRVn-hg@xxxxxxxxxxxxxx
>> Man, you guys respond fast!
>>
>> Russ I tried *7 normally and within the service menu (after *2) - no
>> luck.
>>
>> Rich, I did the *2 and light 7 lit up (failure to communicate). I have
>> armed
>> and disarmed the system successfully multiple times but the light stays
>> on.
>> Seems like there is an extra step to clear it that the user manual won't
>> tell me.
>>
>> Any more ideas???
>>
>> Bruce
>>
>>
>
>




alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home