[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: How to reset service light on CADDX NX-6?



If that's the case the system probably is not programmed to send test
signals...just low battery or power fail, so you should be ok until it tries
to send alarm or trouble signals, then you'll have to do that procedure
again.


"Bruce" <bmwhitetxNOSPAM@xxxxxxxxx> wrote in message
news:wpidnSF_e-8KFajeRVn-uw@xxxxxxxxxxxxxx
| Thanks Allan. That worked like a charm.
|
| Hopefully this won't happen a lot. We have lived here about 5 months and
| this was the first occurrence - due to a lengthy power outage we had.
|
|
| "Allan Waghalter" <awaghalter@xxxxxxxxxxx> wrote in message
| news:LteZe.1194$4u4.317@xxxxxxxxxxxxxxxxxxxxxxxxxxxxx
| > You can't clear the "Fail to Communicate" without sending a  good
| > communication to a central station.  However, you can power down and
then
| > power back up.... (Remove Battery wire, then remove one side of the AC
to
| > power down.  To Power up, Connect the AC power first, then the battery).
| > This will clear the problem until it attempts to send another
| > communication. Then you will have to repeat the above procedure.
| >
| >
| > "Bruce" <bmwhitetxNOSPAM@xxxxxxxxx> wrote in message
| > news:YeednYXkDdUqx6jeRVn-hg@xxxxxxxxxxxxxx
| >> Man, you guys respond fast!
| >>
| >> Russ I tried *7 normally and within the service menu (after *2) - no
| >> luck.
| >>
| >> Rich, I did the *2 and light 7 lit up (failure to communicate). I have
| >> armed
| >> and disarmed the system successfully multiple times but the light stays
| >> on.
| >> Seems like there is an extra step to clear it that the user manual
won't
| >> tell me.
| >>
| >> Any more ideas???
| >>
| >> Bruce
| >>
| >>
| >
| >
|
|
|




alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home