[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: How to reset service light on CADDX NX-6?



You can't clear the "Fail to Communicate" without sending a  good
communication to a central station.  However, you can power down and then
power back up.... (Remove Battery wire, then remove one side of the AC to
power down.  To Power up, Connect the AC power first, then the battery).
This will clear the problem until it attempts to send another communication.
Then you will have to repeat the above procedure.


"Bruce" <bmwhitetxNOSPAM@xxxxxxxxx> wrote in message
news:YeednYXkDdUqx6jeRVn-hg@xxxxxxxxxxxxxx
> Man, you guys respond fast!
>
> Russ I tried *7 normally and within the service menu (after *2) - no luck.
>
> Rich, I did the *2 and light 7 lit up (failure to communicate). I have
> armed
> and disarmed the system successfully multiple times but the light stays
> on.
> Seems like there is an extra step to clear it that the user manual won't
> tell me.
>
> Any more ideas???
>
> Bruce
>
>




alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home