[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: NEED HELP SAFEWATCH PRO 3000EN



# then 20 give you Installer Code, write it down, # 21 give you next =
entery, write it down... # lets you see what in the field...go through =
them all and write down whats already in the panel...write it on a =
programming sheet that way you have a record of it.

* lets  you change the field, # just lets you see whats there.

Again...if you are monitored by ADT or anyone else...don't mess with =
this stuff - it may end up costing you a LOT more than just a service =
call for them to fix it if you screw up the programming.



"." <.@xxxxxxxxx> wrote in message =
news:K_j6e.44599$vL3.3051@xxxxxxxxxxxxxxxxxxxxxxxxx
> Ok, How do I go thru the entries and what an I looking for?
>=20
> "Crash Gordon=AE" <NONE@xxxxxxxx> wrote in message=20
> news:eKi6e.63$yB.768@xxxxxxxxxxxxxxxxxx
> Yes. Thats sounds like you're in programming.
>=20
> 9 points + 2 keyfobs... the keyfobs take up zones you know...you'd =
have know=20
> how many buttons on each keyfob are being used.
>=20
> SA5882 is a Canadian part number for 5881..but I can't remember how =
many=20
> zones it would handle....lemme check. If it's 16 you are gonna close.=20
> 5881L=3D8, 5881M=3D16, 5881H=3D32..
>=20
> You may want to, in the mean time, go through each programming field =
with=20
> #20, #21...etc. and write down all the entries that are in there now =
on a=20
> programming sheet...so if  you mess up at least you have a record of =
what=20
> was there.
>=20
> *99 to get out of programming.
>=20
>=20
>=20
>=20
>=20
>=20
> "." <.@xxxxxxxxx> wrote in message=20
> news:NZg6e.52126$vK6.50876@xxxxxxxxxxxxxxxxxxxxxxxxx
> > There are eight points, one motion, and 2 key fobs.
> > I have an installer code, however you know when you told me that I =
use=20
> > (Then
> > just go into programming, Installer Code + Code 00, then to %56 to =
add the
> > xtmr.)  That does not get me into the programming mode.  I can get =
into it
> > where it says Field? and then goto *56, it then says: SET TO =
CONFIRM?
> > Is that the same place?
> >
> > I am still trying to find the model number of the reciever I found=20
> > something
> > SA5882??
> >
> >
> > "Crash Gordon=AE" <NONE@xxxxxxxx> wrote in message
> > news:6gd6e.10$4z4.737@xxxxxxxxxxxxxxxxxx
> > That'd be 6160V (V for Voice...I think). Yes, you can program with =
that=20
> > one
> > (99% sure anyway...I've not used that one). But you will know for =
certain
> > when you get to *56 field which is where the zone programming =
begins...if=20
> > it
> > doesn't say "Field?" then you can't use it...but pretty sure you =
can.
> >
> > So what kind of reciever does it have and how many wireless points =
are you
> > currently using? Including keyfobs or wireless keypads (like 5800BD) =
if=20
> > any?
> >
> > Do you know the Installer Code?
> > Is it monitored by ADT still?
> >
> >
> >
> >
> >
> > "." <.@xxxxxxxxx> wrote in message
> > news:zzc6e.49288$f%4.14586@xxxxxxxxxxxxxxxxxxxxxxxxx
> > > Here is a picture of the case, there are two numbers listed.  One =
on a
> > > sticker that reads 6160V ADT, the other is stamped on the plastic =
it=20
> > > reads
> > > M6924, whick one is the model # ?
> > > "Crash Gordon=AE" <NONE@xxxxxxxx> wrote in message
> > > news:Ynb6e.2$yB.104@xxxxxxxxxxxxxxxxxx
> > > Of what, the keypad?...you'd have to open it up..or describe it=20
> > > here...or
> > > go
> > > to Ademco's website and see if you can match it up with a pix =
there. The
> > > model number is not usually on the keypad..its usually inside on =
the
> > > board.
> > > ADT's numbers will be the same as Ademco's.
> > >
> > > The reciever model is on the reciever's board, open the can - the=20
> > > reciever
> > > is the circuit board above the main board the model number is part =
of=20
> > > the
> > > circuit board traces (top middle). If there is no reciever in the =
can,=20
> > > and
> > > you DO have wireless points on the system, you may have a keypad =
with RF
> > > reciever  built into it.
> > >
> > > BTW... IF you are still monitored by ADT do NOT mess with it...you
> > > probably
> > > can't if you are still monitored anyway.
> > >
> > >
> > >
> > >
> > > "." <jpmk@xxxxxxxxxxxxx> wrote in message
> > > news:Yx36e.37119$UW6.35553@xxxxxxxxxxxxxxxxxxxxxxxxx
> > > > Where would you find the model number?
> > > >
> > > > "Crash Gordon=AE" <NONE@xxxxxxxx> wrote in message
> > > > news:YS06e.789$AV3.1393@xxxxxxxxxxxxxxxxxx
> > > > It's the same as Vista 20P (pretty much).
> > > >
> > > > You'll need a programming keypad 6139 etc.
> > > >
> > > > You need to know if you have any room left on the =
reciever...check the
> > > > receiver model #...is it a 5881L, 5881M, 5881H. Also, how many =
xtmrs=20
> > > > are
> > > > on
> > > > it now..including any keyfobs, pirs, gbs, wireless smokes, etc.
> > > >
> > > > Then just go into programming, Installer Code + Code 00, then to =
%56=20
> > > > to
> > > > add
> > > > the xtmr.
> > > >
> > > >
> > > > "." <jpmk@xxxxxxxxxxxxx> wrote in message
> > > > news:K606e.36791$UW6.14989@xxxxxxxxxxxxxxxxxxxxxxxxx
> > > > > How does one add a wireless X-mitter.  And where can I get the
> > > > > Installer
> > > > > manual for this system?
> > > > >
> > > > >
> > > >
> > > >
> > > >
> > >
> > >
> > >
> >
> >
> >=20
>=20
>


alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home