Re: Newbe Vista-20P question
On 06/14/2014 06:24 AM, JoeRaisin wrote:
> On 6/13/2014 4:22 PM, James Gang wrote:
>>
>> Fault 07 means zone 7? The resistors are new.
>>
>
> Dude- I once bought a whole new pack of resistors that were all dead short.
>
> Now-a-days, I will generally meter resistors before I use them.
>
> When troubleshooting, NEVER assume new means good....
>
>
> ---
> This email is free from viruses and malware because avast! Antivirus
> protection is active.
> http://www.avast.com
>
take a voltmeter reading across each zone. with only resistors
attached, all should be the same with the possible exception of the
smoke and/or other 2 wire devices zone. If not, check the resistors, as
mentioned (remember murphy's law) and your wiring. If that does not
solve it, you probably have a bad zone on the board.
John