Re: LYNXR chime reminder
"Robert L Bass" wrote:
>
> Yes again. Use the RB3008 board to get timed outputs. I posted the method
> several years ago in a discussion about automatically closing and then
> protecting a garage after door several minutes if it accidentally gets left
> open.
In Quickloader for Windows v5.6.3 after freating the account go to the
"External Relay Control" tab in the "System Assignment" screen. There you can
select relays to trigger and set timeouts ehich can be associated with zone
violations, zone restorals, etc. To get an action to occur for yy seconds but
not until nn seconds after a zone violates, trigger two relays with their
outputs wired in series, but one through NO and the other through NC. The
first relay trips and times out after nn seconds. The second relay trips and
stays transferred for nn+yy seconds. Set the relays to "Follow Zone Open" if
it's a normally closed or EOL supervised loop.
--
Regards,
Robert L Bass
==============================>