Roland Moore wrote:
> I don't know that that a Pro3000 is a Vista 20P. But if it is a Vista 20P it
> should be easy to do with a Ademco 4204.
> Program 20P for using the 4204 the relay(s) for trigger type 2 and zone type
> 20, 21 or 22 and device action of 2 or 4 and the respective device (relay)
> number. That is all depending on exactly what relay you wish to use and the
> relay action you want it to be. You will have to have a keypad like a 6160
> or use Compass software (not available to anyone but ADT for ADT brand
> panels). Programming relays on any Ademco panel can be a bit "funny". Many
> times there are several ways to program the relays to get the same end
> result.
>
> From the instructions:


<snip>


He doesn't need a 4204.  He can use the onboard trigger output to fire a
12 volt relay (which would be cheaper than buying the 4204 or the 4229
zone expansion module).  If he already has the 4229 zone expander, it
comes with relays on board.

The point is he obviously doesn't know how to program the unit (or
doesn't have the manual).  He hasn't given us enough information about
his setup.