Re: Strange Phone Line Issue



What's the voltage on the line?

I've had problem with voltage drop on rural service.

I even have a Vista 15 that even though the voltage is good it does the same
thing you describe (fortunately he's a local) but I can't remote program and
never did find out what the prob was...probably noise but I don't have tools
to measure that.


"ABLE_1" <royboynospam@xxxxxxxxxxxxx> wrote in message
news:SI2dnUdZd-vMoDnYnZ2dnUVZ_t6qnZ2d@xxxxxxxxxxxxxx
| >I thought the telco system sent the caller ID data between 1st and 2nd
| >ring. Maybe that is what you heard?
|
| I have never heard the CID before on any other line as I did on this one.
| It really sounds like a modem carrier for about 1 second.  I turned off
the
| CID on the line and tried again just to check and got the same result.
| Although now that I think about it when I turned it off that was for
| outgoing calls.
|
| I had a conversation with an associate earlier and he said that it maybe
| possible that Verizon has another line crossed onto this line pair.  He
said
| that he had seen it happen on another carrier a few years ago.  Need to
| investigate this possibility further.
|
| Thanks for the inputs so far.  Every little bit helps.
|
| Les
|
|
|
|
|
| > "ABLE_1" <royboynospam@xxxxxxxxxxxxx> wrote in message
| > news:spCdnasiuuNcuznYnZ2dnUVZ_q6vnZ2d@xxxxxxxxxxxxxx
| >> Nick, thanks for the response.  But, please re-read my post especially
| >> this paragraph.
| >>
| >>>> To bring this narrative ahead a bit, I ended up at the demarc and
with
| >>>> the house, panel and all disconnected so that I was connected direct
| >>>> from the CO and the following was observed.
| >>>>
| >>>> On the speaker of the butt set just before the 1st ring a small buzz
| >>>> click was heard and then after the first ring a carrier tone is heard
| >>>> for about 1 second and then a pause and then the next ring.  Nothing
| >>>> else is heard except for normal rings after that.
| >>
| >> I am still puzzled???
| >>
| >> TIA
| >>
| >> Les
| >>
| >>
| >>
| >>> Do you have a RJ31x  ESSEX DSL filter
| >>> I have found DSL screws with up load down load.tones
| >>> and by having the rj block filter it stops it.
| >>> Also did they add sattelite dish some times the cable and or dish box
| >>> has a phone connection that will screw with phone line as well was
this
| >>> recently added.
| >>> Worse comes to worse take all phones off gray brown telco wires and
try
| >>> download to see if problem is with in house wiring or comming in from
| >>> pole .
| >>> I have seen DSL cause all kinds of strange problems even when you
think
| >>> you have everything filtered and some one adds an exstension etc and
| >>> does not do it right.
| >>> DSC modems are very suseptable to dsl
| >>>
| >>> "ABLE_1" <royboynospam@xxxxxxxxxxxxx> wrote in message
| >>> news:9eGdnTRdTcwxgDnYnZ2dnUVZ_segnZ2d@xxxxxxxxxxxxxx
| >>>> Had a strange occurrence today with a customers phone line that is
| >>>> still un-resolved.  Thought I would share and see if anyone has any
| >>>> hints as to what's going on.
| >>>>
| >>>> Customer has one phone line.
| >>>> Standard set up with RJ31X.
| >>>> Phone line has DSL
| >>>> DSL Filters installed.
| >>>> System Communicates Signals to CS, all good
| >>>> Normal phones in house with Answering Machine and CID Box
| >>>> Previous connection for UpDownload OK.
| >>>>
| >>>> Problem comes up when I try to connect to panel remotely.  Panel will
| >>>> hang and then disconnect.  Went to site today and used my laptop to
| >>>> connect to the panel thru my "private phone company in a box" which
| >>>> would be the same as connecting over the phone line.  Connection is
| >>>> good and data transferred as it should.
| >>>>
| >>>> Connected my Butt Set to the phone line and dialed with my cell phone
| >>>> to trigger the panel to answer, Answering Machine Bypass function
| >>>> enabled. While listening to the amplified speaker I heard what
sounded
| >>>> like a modem answering with a carrier tone after the first ring.
| >>>>
| >>>> To bring this narrative ahead a bit, I ended up at the demarc and
with
| >>>> the house, panel and all disconnected so that I was connected direct
| >>>> from the CO and the following was observed.
| >>>>
| >>>> On the speaker of the butt set just before the 1st ring a small buzz
| >>>> click was heard and then after the first ring a carrier tone is heard
| >>>> for about 1 second and then a pause and then the next ring.  Nothing
| >>>> else is heard except for normal rings after that.
| >>>>
| >>>> It is as if another modem or panel is on the line and connecting on
the
| >>>> first ring but not answering the call.
| >>>>
| >>>> Has anyone experienced anything like this and/or what the blazes is
it
| >>>> or could it be?????????   I ran out of time to investigate it further
| >>>> on site with voltages, current, etc. but it seems very strange.  Any
| >>>> thoughts from the masses would be welcome.
| >>>>
| >>>> Thanks,
| >>>>
| >>>> Les
| >>>>
| >>>>
| >>>>
| >>>>
| >>>>
| >>>
| >>>
| >>
| >>
| >
| >
|
|