Re: Strange Phone Line Issue



I thought the telco system sent the caller ID data between 1st and 2nd ring.
Maybe that is what you heard?
"ABLE_1" <royboynospam@xxxxxxxxxxxxx> wrote in message
news:spCdnasiuuNcuznYnZ2dnUVZ_q6vnZ2d@xxxxxxxxxxxxxx
> Nick, thanks for the response.  But, please re-read my post especially
> this paragraph.
>
>>> To bring this narrative ahead a bit, I ended up at the demarc and with
>>> the house, panel and all disconnected so that I was connected direct
>>> from the CO and the following was observed.
>>>
>>> On the speaker of the butt set just before the 1st ring a small buzz
>>> click was heard and then after the first ring a carrier tone is heard
>>> for about 1 second and then a pause and then the next ring.  Nothing
>>> else is heard except for normal rings after that.
>
> I am still puzzled???
>
> TIA
>
> Les
>
>
>
>> Do you have a RJ31x  ESSEX DSL filter
>> I have found DSL screws with up load down load.tones
>> and by having the rj block filter it stops it.
>> Also did they add sattelite dish some times the cable and or dish box has
>> a phone connection that will screw with phone line as well was this
>> recently added.
>> Worse comes to worse take all phones off gray brown telco wires and try
>> download to see if problem is with in house wiring or comming in from
>> pole .
>> I have seen DSL cause all kinds of strange problems even when you think
>> you have everything filtered and some one adds an exstension etc and does
>> not do it right.
>> DSC modems are very suseptable to dsl
>>
>> "ABLE_1" <royboynospam@xxxxxxxxxxxxx> wrote in message
>> news:9eGdnTRdTcwxgDnYnZ2dnUVZ_segnZ2d@xxxxxxxxxxxxxx
>>> Had a strange occurrence today with a customers phone line that is still
>>> un-resolved.  Thought I would share and see if anyone has any hints as
>>> to what's going on.
>>>
>>> Customer has one phone line.
>>> Standard set up with RJ31X.
>>> Phone line has DSL
>>> DSL Filters installed.
>>> System Communicates Signals to CS, all good
>>> Normal phones in house with Answering Machine and CID Box
>>> Previous connection for UpDownload OK.
>>>
>>> Problem comes up when I try to connect to panel remotely.  Panel will
>>> hang and then disconnect.  Went to site today and used my laptop to
>>> connect to the panel thru my "private phone company in a box" which
>>> would be the same as connecting over the phone line.  Connection is good
>>> and data transferred as it should.
>>>
>>> Connected my Butt Set to the phone line and dialed with my cell phone to
>>> trigger the panel to answer, Answering Machine Bypass function enabled.
>>> While listening to the amplified speaker I heard what sounded like a
>>> modem answering with a carrier tone after the first ring.
>>>
>>> To bring this narrative ahead a bit, I ended up at the demarc and with
>>> the house, panel and all disconnected so that I was connected direct
>>> from the CO and the following was observed.
>>>
>>> On the speaker of the butt set just before the 1st ring a small buzz
>>> click was heard and then after the first ring a carrier tone is heard
>>> for about 1 second and then a pause and then the next ring.  Nothing
>>> else is heard except for normal rings after that.
>>>
>>> It is as if another modem or panel is on the line and connecting on the
>>> first ring but not answering the call.
>>>
>>> Has anyone experienced anything like this and/or what the blazes is it
>>> or could it be?????????   I ran out of time to investigate it further on
>>> site with voltages, current, etc. but it seems very strange.  Any
>>> thoughts from the masses would be welcome.
>>>
>>> Thanks,
>>>
>>> Les
>>>
>>>
>>>
>>>
>>>
>>
>>
>
>