[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Suggestions for (Low) Temperature and Water alarms



DMP doesn't need a special model of temp sensor, the Winland is fine (the
one RLB posted) -  you will need to program & wire it in it in the panel
correctly. I usually program them as Aux response zones in DMP
panels...you'll eat up 2 zones one for hi temp one for low.

You'll need 5 conductors... +/- power, and three conductors for the loops if
using both the high and low temp...one high, one low, one common.



"blueman" <NOSPAM@xxxxxxxxxx> wrote in message
news:m2fyl2w7t3.fsf@xxxxxxxxxxxxxxxxxxxx
| We have a DMP XR200L based wired alarm system consisting currently of
| smokes, door/window sensors, and motion sensors.
|
| I would like to add a water sensor in the basement and at least one
| temperature sensor.
|
| I would like the temperature sensor to be small and unobtrusive yet
| adjustable if possible.
|
| Any suggestions on brands and models to consider that would be
| compatible and consistent with my alarm system.
|
| Thanks
|