It gives me an error abt either modem picked up mistakenly or something like
that.
I can handle FA panels...but not ADT.
The panel is a 20P v3 (I think it's a 3...I just installed it 3 months
ago..not a takeover)

I'm wondering if I have a mislabeled panel?

How can you measure noise? That's what Ademco is telling me it "might" be a
noisy line...to me this sounds as believable as an inverted data bit :-)


"Jim Rojas" <jrojas@xxxxxxxxxxxx> wrote in message
news:ebU%e.8947$UD6.1075@xxxxxxxxxxx
| Have the panel call you (installer code # 1). If the panel version is
| incorret, it will tell you exactly what panel you have after it
disconnects.
| I use this feature all the time for unknown panel types. If it is an ADT
or
| First Alert version, it will tell you so.
|
| Jim Rojas
|
|
| "Crash Gordon" <webmaster@xxxxxxxxxxxxxxxxxxxxx> wrote in message
| news:46U%e.5$Af.249@xxxxxxxxxxxxxxxxxx
| >I have one 20P that just refuses to talk to Compass..driving me nuts.
| > Telco voltage 52v - can't tell abt noise...at least it doesnt sound
noisy.
| > *96'd it 3 times
| > I even had Ademco try to connect and they get the same error.
| > I have a feeling that they sold me a mislabeled proprietary panel but
they
| > say; no.
| > We even disconnected every phone on the premises...no go.
| >
| > The only thing I can figure is that it's on a podunk baby phone co.
system
| > out in the boonies - but even that doesn't make too much sense cause
I've
| > talked to other panels in the same area without a problem.
| >
| >
| > <thesatguy1@xxxxxxxxxxxxx> wrote in message
| > news:oCT%e.37$dB4.35@xxxxxxxxxxxxxxxxxxxxxxxxxxxxx
| > | The password is wrong and the panel will hang up every time.
| > |
| > | "Don" <dgp0@xxxxxxxxxxxxx> wrote in message
| > | news:1128216006.581040.242190@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
| > | > Hello to All,
| > | > 01 Problem: Ademco 50P panel dumps central station immediately after
| > | > answering their dial in for setup.
| > | >
| > | > 02 Background: self-installed.  1 Ademco 50p panel; 1 12-volt, 7-amp
| > | > battery at auxiliary power; 1 4208U expansion cards, currently.
| > | >
| > | > 03 Currently connected: 2 2-wire heat, 1 4-wire CO, 12 4-wire
smokes.
| > | > 10K EOL resistors are wired at each detector rather than in the
panel
| > | > and expansion card. The first 8 detectors are wired directly to the
| > | > panel, jumper wired at zone 9,  next 7 (10-16) to the expansion.
| > | >
| > | > No problem indicated at keypad.
| > | >
| > | > 04 I may have programmed something at the keypad called Jumper. I
have
| > | > to find it again.
| > | >
| > | > 05  My panel is in New York City. Called internet monitoring
service,
| > | > central station in California.  Programmed their numbers while they
| > | > instructed over separate telephone line.  When they dial into the
| > | > Vista-50p over its own hardwired, dedicated telephone line, the
panel
| > | > seems to negotiate with their modem then immediately hangs up.
| > | >
| > | > NY telco says the line is noiseless which it does seem to be.
Ademco
| > | > dialed in at request of central station and said the communicator
was
| > | > bad.  I bought and installed a whole new panel! Problem persisted.
| > | > Local installer said I had to use an RJ31X so I installed one.
| > Problem
| > | > still persists.  Central Station never heard of this problem.  Three
| > | > local installers also never heard of it.  Ademco/Honeywell will not
| > | > talk to me.
| > | >
| > | > I am up against a deadline from my insurer to have this system
| > | > monitored.
| > | >
| > | > Any and all help is appreciated... and desperately needed.
| > | >
| > | > TIA
| > | >
| > | > Don
| > | >
| > |
| > |
| > |
| >
| >
|
|