Re: Ademco:PanelDumpsCentralStation



Have the panel call you (installer code # 1). If the panel version is
incorret, it will tell you exactly what panel you have after it disconnects.
I use this feature all the time for unknown panel types. If it is an ADT or
First Alert version, it will tell you so.

Jim Rojas


"Crash Gordon" <webmaster@xxxxxxxxxxxxxxxxxxxxx> wrote in message
news:46U%e.5$Af.249@xxxxxxxxxxxxxxxxxx
>I have one 20P that just refuses to talk to Compass..driving me nuts.
> Telco voltage 52v - can't tell abt noise...at least it doesnt sound noisy.
> *96'd it 3 times
> I even had Ademco try to connect and they get the same error.
> I have a feeling that they sold me a mislabeled proprietary panel but they
> say; no.
> We even disconnected every phone on the premises...no go.
>
> The only thing I can figure is that it's on a podunk baby phone co. system
> out in the boonies - but even that doesn't make too much sense cause I've
> talked to other panels in the same area without a problem.
>
>
> <thesatguy1@xxxxxxxxxxxxx> wrote in message
> news:oCT%e.37$dB4.35@xxxxxxxxxxxxxxxxxxxxxxxxxxxxx
> | The password is wrong and the panel will hang up every time.
> |
> | "Don" <dgp0@xxxxxxxxxxxxx> wrote in message
> | news:1128216006.581040.242190@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
> | > Hello to All,
> | > 01 Problem: Ademco 50P panel dumps central station immediately after
> | > answering their dial in for setup.
> | >
> | > 02 Background: self-installed.  1 Ademco 50p panel; 1 12-volt, 7-amp
> | > battery at auxiliary power; 1 4208U expansion cards, currently.
> | >
> | > 03 Currently connected: 2 2-wire heat, 1 4-wire CO, 12 4-wire smokes.
> | > 10K EOL resistors are wired at each detector rather than in the panel
> | > and expansion card. The first 8 detectors are wired directly to the
> | > panel, jumper wired at zone 9,  next 7 (10-16) to the expansion.
> | >
> | > No problem indicated at keypad.
> | >
> | > 04 I may have programmed something at the keypad called Jumper. I have
> | > to find it again.
> | >
> | > 05  My panel is in New York City. Called internet monitoring service,
> | > central station in California.  Programmed their numbers while they
> | > instructed over separate telephone line.  When they dial into the
> | > Vista-50p over its own hardwired, dedicated telephone line, the panel
> | > seems to negotiate with their modem then immediately hangs up.
> | >
> | > NY telco says the line is noiseless which it does seem to be.  Ademco
> | > dialed in at request of central station and said the communicator was
> | > bad.  I bought and installed a whole new panel! Problem persisted.
> | > Local installer said I had to use an RJ31X so I installed one.
> Problem
> | > still persists.  Central Station never heard of this problem.  Three
> | > local installers also never heard of it.  Ademco/Honeywell will not
> | > talk to me.
> | >
> | > I am up against a deadline from my insurer to have this system
> | > monitored.
> | >
> | > Any and all help is appreciated... and desperately needed.
> | >
> | > TIA
> | >
> | > Don
> | >
> |
> |
> |
>
>