[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: need help with Northern N-1000-IV panel



Absolutely correct - PX4H cards work perfectly.
 Thanks to all who gave this one a thought.



"petem" <petem001@xxxxxxxxx> wrote in message
news:Yfb4f.30962$Tn2.683849@xxxxxxxxxxxxxxxxxxxxxx
> if my memory is right the controller already have a few card format in
> memory and 26 bit is included in those
>
>
> "Jackcsg" <nospam@xxxxxxxxxx> a écrit dans le message de news:
> U8CdnU-919Vld83enZ2dnUVZ_tCdnZ2d@xxxxxxxxxxxxxxx
>> Sounds like a reader issue. What bit set do you have the reader data set
>> to?
>> If memory serves me, the panel default is 37 bit. If you're using a 26
>> bit
>> standard reader...there's your problem. Check your card format
>> information.
>>
>> "alex rogozin" <arogozin at comcast period net> wrote in message
>> news:4J-dnUIAd_LLys3eRVn-iA@xxxxxxxxxxxxxx
>>> i did buffer, unbuffer, initialize, re-created databases and created new
>>> ones as described in described order.
>>> from "Panel Control" relay energizes, de-energizes, pulses fine.
>>> the readers i use are HID  ProxPro 2, cards are 5 digit HID. The reader
>>> board pulses as described during card read. "reverse LED" under panel -
>>> readers does not work.
>>> reader issue ? my next step is to get mag reader and try that one.
>>> If someone could post or email working backup of the system i could also
>> try
>>> that approach.
>>>
>>> Thanks to all reading this and trying to help.
>>> Regards,
>>> Alex
>>>
>>>
>>>
>>> "petem" <petem001@xxxxxxxxx> wrote in message
>>> news:l0W3f.22724$Tn2.456984@xxxxxxxxxxxxxxxxxxxxxx
>>> > did he unbuffer the panel at log on?
>>> >
>>> >
>>> > "alex rogozin" <arogozin at comcast period net> a écrit dans le
>>> > message
>> de
>>> > news: 0v-dnZzls4MQntLeRVn-iQ@xxxxxxxxxxxxxx
>>> >> I'm not even getting invalid card reads - bad panel ?
>>> >>
>>> >>
>>> >> "Jackcsg" <nospam@xxxxxxxxxx> wrote in message
>>> >> news:us2dneOkWeItJdreRVn-vw@xxxxxxxxxxxxxxx
>>> >>> Check your Time Zones. Sounds like you're getting invalid card
>>> >>> reads.
>>> >>>
>>> >>> "alex rogozin" <arogozin at comcast period net> wrote in message
>>> >>> news:6YednXO5GeB-XdjeRVn-rg@xxxxxxxxxxxxxx
>>> >>>> need help with setting up 1000-4 panel - v8.02 win-pak 1.17
>>> >>>> connected
>>> >>>> through serial, HID prox receiver, HID cards.
>>> >>>> created databases, did everything by the manual ( or maybe missed
>>> >>>> something ) - panel control works fine, relays energize, panel
>>> >>>> appear
>>> >>>> to
>>> >>>> work. On card read green light on the 4-reader board goes steady
>>> >>>> for
>>> >>>> 1/2
>>> >>> sec
>>> >>>> as described - no messaged in win-pak and no relay action - what
>>> >>>> did
>> i
>>> >>> miss
>>> >>>> ?
>>> >>>> Any help appreciated.
>>> >>>> Also - will any RS232 to RS485 converters work or i must get
>>> >>>> Northern
>>> >>> C-100
>>> >>>> or N-485 ?
>>> >>>>
>>> >>>> Regards,
>>> >>>> Alex
>>> >>>>
>>> >>>>
>>> >>>
>>> >>>
>>> >>
>>> >>
>>> >
>>> >
>>>
>>>
>>
>>
>
>