[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: need help with Northern N-1000-IV panel



if my memory is right the controller already have a few card format in
memory and 26 bit is included in those


"Jackcsg" <nospam@xxxxxxxxxx> a écrit dans le message de news:
U8CdnU-919Vld83enZ2dnUVZ_tCdnZ2d@xxxxxxxxxxxxxxx
> Sounds like a reader issue. What bit set do you have the reader data set
> to?
> If memory serves me, the panel default is 37 bit. If you're using a 26 bit
> standard reader...there's your problem. Check your card format
> information.
>
> "alex rogozin" <arogozin at comcast period net> wrote in message
> news:4J-dnUIAd_LLys3eRVn-iA@xxxxxxxxxxxxxx
>> i did buffer, unbuffer, initialize, re-created databases and created new
>> ones as described in described order.
>> from "Panel Control" relay energizes, de-energizes, pulses fine.
>> the readers i use are HID  ProxPro 2, cards are 5 digit HID. The reader
>> board pulses as described during card read. "reverse LED" under panel -
>> readers does not work.
>> reader issue ? my next step is to get mag reader and try that one.
>> If someone could post or email working backup of the system i could also
> try
>> that approach.
>>
>> Thanks to all reading this and trying to help.
>> Regards,
>> Alex
>>
>>
>>
>> "petem" <petem001@xxxxxxxxx> wrote in message
>> news:l0W3f.22724$Tn2.456984@xxxxxxxxxxxxxxxxxxxxxx
>> > did he unbuffer the panel at log on?
>> >
>> >
>> > "alex rogozin" <arogozin at comcast period net> a écrit dans le message
> de
>> > news: 0v-dnZzls4MQntLeRVn-iQ@xxxxxxxxxxxxxx
>> >> I'm not even getting invalid card reads - bad panel ?
>> >>
>> >>
>> >> "Jackcsg" <nospam@xxxxxxxxxx> wrote in message
>> >> news:us2dneOkWeItJdreRVn-vw@xxxxxxxxxxxxxxx
>> >>> Check your Time Zones. Sounds like you're getting invalid card reads.
>> >>>
>> >>> "alex rogozin" <arogozin at comcast period net> wrote in message
>> >>> news:6YednXO5GeB-XdjeRVn-rg@xxxxxxxxxxxxxx
>> >>>> need help with setting up 1000-4 panel - v8.02 win-pak 1.17
>> >>>> connected
>> >>>> through serial, HID prox receiver, HID cards.
>> >>>> created databases, did everything by the manual ( or maybe missed
>> >>>> something ) - panel control works fine, relays energize, panel
>> >>>> appear
>> >>>> to
>> >>>> work. On card read green light on the 4-reader board goes steady for
>> >>>> 1/2
>> >>> sec
>> >>>> as described - no messaged in win-pak and no relay action - what did
> i
>> >>> miss
>> >>>> ?
>> >>>> Any help appreciated.
>> >>>> Also - will any RS232 to RS485 converters work or i must get
>> >>>> Northern
>> >>> C-100
>> >>>> or N-485 ?
>> >>>>
>> >>>> Regards,
>> >>>> Alex
>> >>>>
>> >>>>
>> >>>
>> >>>
>> >>
>> >>
>> >
>> >
>>
>>
>
>




alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home