[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Programming problem on Vista 20P



One keypad should be 16, the other 17

You also have to enable the use of the second keypad at address *191 (I =
think its 191) by entering 11 there. This should fix at least the Check =
100.

You know how to change the keypad addresses right? ... hold down the 1 & =
3 keys immediately after powering up the keypads.

You may have more probs...but thats all i remember without getting a =
programming sheet out...(later on this)




"Mike" <reply@xxxxxxxxxxxxxx> wrote in message =
news:EImdnWulaJRCA_ffRVn-jg@xxxxxxxxxxxxxx
> I have a 20P with 2 keypads. A 6160 and a 6150RF.
> Had everythng programmed and seemingly working fine on the bench. =
(good=20
> advice guys thanks)
> I initially programmed the 5804 Keyfob via the 6150RF keypad. It =
worked well=20
> although i couldnt figure out how to change one of the buttons to be =
used as=20
> a panic button.
> I decided in my infinite greeny wisdom to try reprogramming the keyfob =
from=20
> the 6160 keypad using the #3 template via *58.
> After doing this i now get the error "Check 100 RF Receiver" according =
to=20
> the info in the install and setup guide this indicates that =
"communication=20
> between control and a zone expander or wireless receiver is =
interupted.=20
> Where xx is the device address." So i know that 01 is the device =
address for=20
> the 6150RF, so im not sure where to look in the programming to delete =
the=20
> mistake i just made by going through the *58 Wireless Key Programming=20
> Templates procedure.
> I tried going back and disabling all the zones that were made active =
by=20
> this, and im still getting the same error.
> Funy thing is the 6150RF Keypad is still working, and the keyfob still =
works=20
> as it was when i first programmed it from the 6150RF.
> Somewhere i must have entered in device 00 as the device number for =
the=20
> 6150RF when i was trying to reprogramm the keyfob from the 6160.
> Any Vista 20P gurus care to shed some light on this mess?
>=20
> Thanks=20
>=20
>