Re: CBUS dimmer & GU10 LED not functioning as expected



IIRC, this maybe something to do with a small current path being
needed for the dimmer electronics to function ...

Chris


On 2 Sep 2007, at 13:23, Adrian wrote:

> Have also found out if I plug a normal GU10 bulb in to one of the
> sockets (theres 2 on each run) so theres a normal bulb and a LED
> one it
> works fine
>
>
> Adrian wrote:
>> Hi
>>
>> have a 240v GU10 LED wired to a CBUS dimmer channel and it appears
>> that
>> when the channel is off, i read 50v on the cct (which causes the
LED
>> bulb to glow at about 50%), if I unplug the bulb this drops to 0.
The
>> LED is not a dimmable type and I had configured the channel for
>> instant
>> on/off operation, is this normal for LED bulbs?
>>
>> Am going to cut across to a relay but i though this would of
worked
>>
>> and advice appreciated
>>
>> Adrian
>>
>>
>
>
>
>
>
>