Re: SignaLinc Repeater 3-Wire Dryer - No Dim with Active Home Programs
In article <sl2Wh.5007$2v1.1466@xxxxxxxxxxxxxxxxxxxxxxxxxx>, actodesco@xxxxxxxxx (Art Todesco) writes:
| So Dan, things like the 1132CU have
| these similar problems?
The 1132 is itself a controller so you probably wouldn't be using it
with Active Home [Pro]. The last generation of problem involved some
SwitchLincs not responding to CM11a (Active Home) macros because of
(it seemed) a disagreement on the minimum gap between codes. As I
said, I'm having difficulty imagining what they could consider wrong
with a particular string of DIM/BRI commands since there aren't a whole
lot of choices in how to structure such. Also, from the original
poster's description it isn't a matter of merely failing to repeat the
sequence since the DIM/BRI works without the repeater. They must be
actively stepping on the signal. I wonder if they could be colliding
with every other DIM/BRI, turning the sequence into a (perhaps invisible)
number of microDIMs? The light does turn on so something is getting through.
Dan Lanciani