[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Random ALL ON Signals



just a small question,what do you have controlled by this event?

11/9/2006 10:05:00 PM   Info  Device: Outside Front Door Bug Light (C3)

what type of light? anything new on that side?


"The Taz" <TazsNews@xxxxxxxxxxxxx> a écrit dans le message de news:
9445h.38$%U.8@xxxxxxxxxxx
> They are a total mixture. I have some two way modules, some hard wired
> appliance modules, several wall switch modules.
> etc..
> and yes, the ALL ON occured between the 10:05:00 and the 10:05:13
> becuase the 10:05:13 All OFF event was me Manually pressing the all off to
> turn everything off
> i have the at004 currently logging all data frames, but i think you are
> right, since it didnt appear in my homeseer log, i am not going to get any
> record of the event..
> Im going to do it for the heck of it, and then switch to noise logging
> ill keep everyone posted..
>
>
> "Dave Houston" <nobody@xxxxxxxxxxxx> wrote in message
> news:4554937f.503748265@xxxxxxxxxxxxxxxx
>> OK. Are all of the devices affected on wall switches, plug-in modules, a
>> mixture?
>>
>> Some X-10 made wall switches and some plug-in modules can be directly
>> affected by spike type transients and the microcontrollers in them can
>> also
>> be reset by a dip in supply voltage. Until I replaced the (standard)
>> switch,
>> one of my LM14A modules would frequently turn off whenever I turned off
>> an
>> old fluorescent in one bathroom. The spike from the collapsing magnetic
>> field of the ballast was the culprit. A relay type of switch in the
>> bathroom
>> cured it. Others have found that motors starting/stopping can have the
>> same
>> effect.
>>
>> I think your log eliminates the possibility that there is a valid X-10
>> signal on the powerlines (and as I noted there is no All Units ON
>> command).
>> Do you have anything that happens at the time of the mystery events? The
>> change of seasons frequently exposes something like an AC compressor or
>> furnace blower as a noise source.
>>
>> It might be helpful if the AT004 can record line voltage to see if
>> there's a
>> dip that correlates with the events.
>>
>> I'm not clear on one point. Did the All ON event occur between 10:05:00
>> and
>> 10:05:13?
>>
>> "The Taz" <TazsNews@xxxxxxxxxxxxx> wrote:
>>
>>>Ok heres the weird thing, it just happened last night..
>>>I checked the logs on my home seer and heres what i got...
>>>  11/9/2006 10:04:30 PM   X10 Received  B3 (Hallway Light) B Off
>>>  11/9/2006 10:04:39 PM   X10 Received  A12 (Kitchen Water Cooler) A Off
>>>  11/9/2006 10:04:40 PM   X10 Received  A12 (Kitchen Water Cooler) A Off
>>>  11/9/2006 10:04:46 PM   X10 Received  A7 (Living Room Table Lamp) A Off
>>>  11/9/2006 10:05:00 PM   Info  Event Trigger "Front Door Bug Light off
>>> nights"
>>>  11/9/2006 10:05:00 PM   Info  Device: Outside Front Door Bug Light (C3)
>>> OFF
>>>  11/9/2006 10:05:13 PM   X10 Received  F All Units Off
>>>
>>>You can see my F ALL units off code after it happened...
>>>but nothing absolutly nothing in the logs show anything to turn
>>>everything
>>>on.,
>>>And i am a little unsure how to use the AT004, but i am going to try and
>>>set
>>>it up this weeekend.
>>>and thats the weirdest part of it, its eveything, Lamps, Appliances,
>>>alike
>>>all turn on, At the exact same moment, its not a Sequencial thing, its
>>>all
>>>at once.. lights, and a/c's and fans, etc..
>>>I have the following set up in my home
>>>Im Running homeseer
>>>using a ACT TI103 interface...
>>>I also have a Interface/Coupler
>>>Homepro Amplified X10 Coupler Repeater W/ Repeated Signal Detection
>>>http://www.smarthome.com/4821ac.html
>>>In addition to a
>>>      Leviton Whole-House Surge Protector
>>>
>>>http://www.smarthome.com/4860.html
>>>Which i know has no affect on x10.
>>>But that is my set up, I also have one or two RF transceivers i dont
>>>recall
>>>but im pretty sure  NONE of them are on the F house code..
>>>i use a few wireless motion sensors, thats why i use the rf transeivers,
>>>but
>>>they are on a different house code, im pretty sure.
>>>I will try and set up the AT004 this weekend, and keep everyone posted,
>>>any info on this would be awsome though.
>>>P.S Does any one have in use the
>>>Homepro Amplified X10 Coupler Repeater W/ Repeated Signal Detection
>>>http://www.smarthome.com/4821ac.html
>>>and can share with me the ideal dip switch configuration?!
>>>
>>>Thanks
>>>Fred
>>>
>>>
>>>"Dave Houston" <nobody@xxxxxxxxxxxx> wrote in message
>>>news:4552a22d.376434062@xxxxxxxxxxxxxxxx
>>>> "The Taz" <TazsNews@xxxxxxxxxxxxx> wrote:
>>>>
>>>>>Ok, i got a real good one for everyone out there..
>>>>>I have been using the X10 system for several years, and has grown in my
>>>>>home
>>>>>over the years, and now just about includes all my lights and
>>>>>applinaces..
>>>>>I use Homeseer, for timing and controlling, as well as one or two touch
>>>>>screen controllers.
>>>>>Every so often, lately more then not.
>>>>>At random times, everything on my 'F' Code goes ON!
>>>>>Lilghts, A/C, Fans, Etc..
>>>>>If its on the F code, it turns on...
>>>>>It is driving me nuts..
>>>>>i have a AT004 Tester,
>>>>>but am not even sure where to begin.
>>>>>Anyone ever see this?! or have any idea or any help would be so very
>>>>>much
>>>>>appericaited.
>>>>
>>>> Do the logs from your software show a command at the time of the event?
>>>>
>>>> The AT004 specs say, "Can log noise and frame data over a 24 hour
>>>> period."
>>>> Can you use this to log events?
>>>>
>>>> Do both lamp and appliance modules turn on? (There is no single X-10
>>>> command
>>>> that will activate both light and appliance modules.)
>>>>
>>>> What powerline interface do you use?
>>>>
>>>> What RF transceivers are in use?
>>>>
>>>> http://davehouston.net
>>>> http://tech.groups.yahoo.com/group/roZetta/
>>>> roZetta-subscribe@xxxxxxxxxxxxxxx
>>>
>>
>>
>> http://davehouston.net
>> http://tech.groups.yahoo.com/group/roZetta/
>> roZetta-subscribe@xxxxxxxxxxxxxxx
>
>




comp.home.automation Main Index | comp.home.automation Thread Index | comp.home.automation Home | Archives Home