Re: Trouble setting CM11 clock



Even if you send less than seven bytes, the CM11 will set those parameters
for which it has received data. It does not wait for a 0x00 verification.
You can check this by omitting the last byte and then reading the interface
status with 0x8b.

The checksum, 0x00, 0x55 sequence is used only with PLC commands.

"Quina" <carias.joao@xxxxxxxxx> wrote:

>Thank you Dave, your help was really great! However, there is something
>that still makes me a bit confused. Shouldn't the CM11 respond with the
>ready code (0x55) after the "set interface clock" sequence(*)?
>Thank you again,
>
>João Carias
>
>(*) Sequence: 0x9b,... » chkSum  » 0x00