[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Z-WAVE question (Go Insteon!!)



I've been hearing/reading that Insteon is having some of the same comms
problems that X10 did, fewer, but still present.  What is the current
reading on that?  Is UPB any better?

Thanks



"Jack Edin" <nospam@xxxxxxxxxxxxxxxxxx> wrote in message
news:444ACBCA.4000207@xxxxxxxxxxxxxxxxxxxxx
> Frank,
>
> I believe the better method might have been Insteon!
>
> I am biased, as I sell Insteon...
>
> I believe that when you change a switch's state, that information is
> broadcast across the Insteon network.
>
> As such the Elk M1 will be able to hear this, and react - as programmed,
> etc.
>
> I've asked Elk to help me write a set of rules, for their M1 control, to
> take advantage of this very communication. Here is what I have in mind:
>
> ===================
> An Insteon (on/off) switch is installed on a bathroom fan...
>
> You're leaving the room...
>
> Let's say you press the fan's on once. It is locally connected to the
> load, so the fan'll come on. Nothing special.
>
> The signal IS sent across the Insteon network that this switch is now in
> the ON position...
>
> M1 hears it, and sets a counter...
>
> Now say you were to press ON a second time within 5 seconds...
>
> I want the M1 to adjust it's counter, and say "Five minutes"...
>
> Press again, within the allowed period and it ups the timer and
> announces "10..."
>
> Again: "20", "30", "45", "60", "Normal"
>
> If at any time OFF is pressed, the fan goes off... The whole process is
> reset...
>
> So if it's just a little stinky, 5 or 10 minutes oughta do it...
> Take a steamy shower, and maybe you want an hour...
>
> When the time period expires, the M1 will send an OFF command to the fan's
> switch.
> ====================
>
> This would not be possible without Insteon's network communications.
>
> Note: At this time whenever an Insteon switch is dimmed locally, that
> status is not communicated. On and Off are, however.
>
> As an early adopter of Insteon I know I'll have to wait for some new
> products to do everything I'll want, but these things are coming. Some
> very soon. I expect half a dozen new Insteon products in the next six
> months, the first will probably arrive in three...
>
> And unlike X10 the more Insteon devices you have, the better the
> network. Every device acts as a repeater.
>
> I hope this helps!
>
> Jack
> :)
>
> Note:
>
> Insteon offers a switch which has it's own built-in timer already. The
> above is just an example of how Insteon's communication could be used.
>
>
> Frank Olson wrote:
>>
>> You bring up an interesting point, Dennis.  We recently completed an
>> installation where the customer (retired senior airline pilot) wanted a
>> good deal more "bang" for his "buck".  He wanted to know status of
>> practically everything in his house.  This entailed wiring relays in
>> parallel to a number of lighting circuits controlled by X-10 switches.
>> This gives him accurate and up to the minute status on a specific
>> partition display on his alarm system keypads, as well as on custom
>> graphic displays located in his bedroom and office.  You could very
>> easily adapt this to any partitionable hybrid (combination
>> wired/wireless) security system out there.  We installed GRI PB-2020's in
>> the door frames to monitor the status of all the dead-bolts as well. It
>> was a very interesting project, all-in-all.
>>
>> Frank Olson
>> http://www.yoursecuritysource.com




comp.home.automation Main Index | comp.home.automation Thread Index | comp.home.automation Home | Archives Home