Re: New Smarthome Appliance Module



During my several attempts to convert 2001STW module, I discovered that
sometimes the module "locks" and therefore stay unable to interpret new X10
command. Pressing a short time the switch unlock the module without
resetting it. In the observed case, problem was expected to be related to
"local control". May be disabling it will solve your problem. You can
hardwarly disable it by removing the .22K 250V condensator at the most left
side (close to the triac).

I confirm that module could also enter in a "all time blinking" state in
noisy line condition. But, on the basis of my experience, they are more
reliable than X10 module regarding false triggering.

Hope it helps

Thierry
"Dave Houston" <nobody@xxxxxxxxxxxx> wrote in message
news:429e030c.236267852@xxxxxxxxxxxxxxxx
>I pulled the circuit board from a 2000STW to get a closer look. There are
> seven unused PIC16C622A pins which are not terminated, including MCLR and
> one Vss pin. That may be innocuous or it may presage problems in
> electrically noisy environments.
>
> nobody@xxxxxxxxxxxx (Dave Houston) wrote:
>
>>I doubt a filter will help. There is some evidence that the *Linc modules
>>and switches are affected by out-of-band noise that the filters do not
>>block. In my case, X-10 made LM14As worked fine in circuits where 2000STWs
>>would not work reliably. THe LED on the 2000STWs would blink randomly but
>>I
>>could see no noise on the line using a scope and ACT's Scope-Test2.
>>
>>Does their appliance module have an LED? What is it doing when the module
>>is
>>unresponsive?
>>
>>Art Todesco <actodesco@xxxxxxxxx> wrote:
>>
>>>Update from OP:  One of the 3 times this has
>>>happened was most probably NOT a loss
>>>of housecode/unit code.  I still think the first 2
>>>occurrences were.  The 3rd occurrence
>>>was probably a situation where there was some type
>>>of interference preventing
>>>access in that particular location.  This seems to
>>>happen from time to time in my
>>>house.  Next I am going to try one of the whole
>>>house x10 filter units.  I'll keep you
>>>posted.
>>>
>>>Dave Houston wrote:
>>>> I don't know what they use in appliance modules but they use a
>>>> PIC16C622A
>>>> and a 24LC32A (4KB EEPROM) in the 2000STW lamp module. There's no
>>>> reason to
>>>> think that the EEPROM would lose data from power glitches. It's more
>>>> likely
>>>> to be a flaw in the firmware used in the PIC so I agree that replacing
>>>> them
>>>> is probably futile until they find and fix the flaw.
>>>>
>>>> Wayne <wayne@xxxxxxxx> wrote:
>>>>
>>>>
>>>>>Correct, that is not supposed to happen.  But it happens to me
>>>>>occasionally on multiple modules.  I suspect it is related to power
>>>>>line glitches or spikes.  Do you have any idea what is causing yours
>>>>>to reset?
>>>>>
>>>>>I spoke with some SmartHome folks at EHExpo in March and apparently
>>>>>they had heard of modules losing thier settings, but didn't have
>>>>>enough clues at the time to determine a root cause.  I have been
>>>>>unable to force mine to lose thier settings by simulating power
>>>>>fialures.  SmartHome has offered to replace them under warranty, but
>>>>>there isn't much point for me until they fix the issue.
>>>>>
>>>>>On Sun, 29 May 2005 08:59:45 GMT, "BruceR" <brNOSPAM@xxxxxxxxxx>
>>>>>wrote:
>>>>>
>>>>>
>>>>>>Send it back. That's not supposed to happen.
>>>>>>
>>>>>>From:Art Todesco
>>>>>>actodesco@xxxxxxxxx
>>>>>>
>>>>>>
>>>>>>>I have one of those new "wheelless" Smarthome
>>>>>>>appliance modules.  It looses the housecode and/or
>>>>>>>unit code about once per week.  Is this a common
>>>>>>>problem?  Anyone else have this problem?
>>>>>>
>>>>
>