Re: replacement windows and alarm contacts
> The contacts will be recessed into the window frames, and the magnets
> installed in the sash's. However, between the window frame and the
> sash is a gap in which the slide moves vertically to accommodate the
> opening and closing of the window. There are slides on both sides
> which the sash clips in.
>
> My concern is with the gap between the sash and the frame (channel in
> which the slide travels). The gap is 3/4-1". Will stronger magnets
> work as previously suggested, or is there an alternative way of
> installing the contacts?
Hi Jim,
You can install "wide gap" magnetic contacts which have a minimum 1" gap.
Use two magnets, side by side, to further extend the gap of the sensors.
Install the magnets with like poles adjacent (the magnets will try to push
each other away). The resulting gap will be roughly 40-60% greater than
with a single magnet.
Sentrol, GRI, Ademco and a few others make reliable magnetic contacts. Stay
away from Tane.
--
Regards,
Robert L Bass
=============================>
Bass Home Electronics
2291 Pine View Circle
Sarasota · Florida · 34231
877-722-8900 Sales & Tech Support
http://www.bassburglaralarms.com
=============================>