[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Osborne-Hoffman 2000E receiver problem



Before your last comment regarding the buzzer,my thought was that the
receiver ring detect circuit is not working.  If the buzzer is connected
across the phone with, with applicable capacitor or course, the receiver
may still not be detecting ring, just the buzzer is working.  Check the
no. of rings to answer in programming.  Meter the phone line on ringing
to confirm it is 90v AC (approx.).  Switch the phone lines to confirm
that is is the receiver, not the phone lines.
Trace the wiring from the coil of the line seizure relay, backwards,  to
see if there is a hardware issue re: the relay not seizing.  If there
are duplicate circuits for each phone line, compare the circuits with a
meter to determine the difference.  If the receiver uses line cards,
swap them.

These are the ones that jump out at me.  As you dive in, you might find
other related issues,

John









On 03/24/2015 11:39 PM, mleuck wrote:
> On Tuesday, March 24, 2015 at 6:39:19 PM UTC-5, cha...@xxxxxxxxx wrote:
>> To All:
>>
>> Osborne-Hoffman 2000E receiver.
>>
>> Line one functions properly. Line two is the problem. No additional
>> lines.
>>
>> When a signal is sent to line two, the receiver does not seize the
>> line, hence the acknowledge tone is not generated for the xmitter to
>> hear. When calling line two via headset I only hear the phone company
>> generated ring voltage/tone that continues until I hang up. In effect
>> the receiver does not answer when line two is called. Also when line
>> one is busy with a signal, and a second call is sent to line one, the
>> call is routed/hunted to line two, but the receiver still does not
>> answe line two.r.
>>
>> The receiver is aware of the ring voltage coming in on line two,
>> because the receiver sounds it's buzzer, and then the operator
>> silences it.
>>
>> I have a spare OH, but before I go to the CO I thought I's query here
>> for advice.
>>
>> Thanks.  Charlie