Re: Paradox Esprit fails to activate alarm siren in 3 Zones
I tested 2 of the 3 zones about 12 months ago and they activated the
alarm properly. I don't think there's much point in setting up
zones and sensors for these zones only to program them
to be always silent. We also have a bedside keypad
which can generate a panic alarm.
Regards, Joe
"Doug" <not@xxxxxxxx> wrote in message
news:mkNqh.127303$Pv5.113827@xxxxxxxxxxxxxxx
> When was the last time you tested those 3 zones, is it possible that the
> zones have always been silent ?, you may never have noticed before because
> most people don't test every zone individually. Replacing the battery
> shouldn't affect the programming.
>
> Doug
>
> --
>
> "Joe H" <Joe@xxxxxxxx> wrote in message news:45aafb1e$1@xxxxxxxxxxxxxxx
>> Thanks Tourman for these comments. The system was working correctly with
>> no silent zones until recently when we did some tests to see the system
>> worked correctly with the power off. We decided to put in a new battery
>> (as it was 8 years old) and it was after this that we noticed 3 zones had
>> become silent ones. I guess some programming might have been lost as a
>> result of these tests? Before the battery was changed, the outside siren
>> was activated as soon as the power went off, but this hasn't happened
>> since the battery was changed.
>>
>> Regards, Joe