[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Power832 problem - Need immediate help!



Do this:

1. Go into installer level programming.
2. Press 902, then wait one minute while the system polls the devices.
3. Press # #

That should get rid of the general system supervisory.

Jim Rojas



"pawn" <pawn@xxxxxxxxxxxxxxx> wrote in message
news:12sd35r3f28l2cd@xxxxxxxxxxxxxxxxxxxxx
> Frank Olson wrote:
>
>> After you press *2, the "zone 1" light indicates a "general service
>> trouble" on the 832.  You have to press "1" to enter the service trouble
>> menu.  The zone lights that illuminate correspond to the following
>> trouble conditions
>>
>> 1 = system low battery
>> 2 = bell circuit trouble
>> 3 = general system trouble
>> 4 = general system tamper
>> 5 = general system supervisory
>> 6 = not used
>> 7 = PC5204 low battery
>> 8 = PC5204 AC failure
>
> Thanks.  I get a "5".  Again, as far as I know, the system is not
> supervised.  In fact, I just checked again:  section 380, light No. 1 is
> off.  And this after I have successfully powered off the system.  Hmmm...
>
> Any ideas?
>
> Thanks again.




alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home