Re: Ademco 50P - Unable To Disarm



Is this a brownstone in Harlem between Adam Clayton Powell & Frederick
Douglas? I'll have you admitted to Bellevue if you're chopping up one
of those gorgeous homes doing your Charlie Bearie routine.
Put the Mr. Wizard alarm kit away and PLEASE hire a company to install
the system.
Now if it's a Brooklyn brownstone I'll send you a pack of matches so
you can burn it down, hopefully igniting the rest of Brooklyn in the
process.



Don wrote:
> I just posted a reply to James Barnes in re "contact / electrical"
> rating.  When I got back online I saw there were two more responses.
>
> It is good to know the heats and waterflow draw nothing.
>
> Yes, this is the NY brownstone.
>
> If you are in New York, I may take you up on your offer.  Or perhaps
> you know someone in this area who is truly competent and would be
> willing to come into this situation.
>
> I would really like to finish this myself, however, since I seem to be
> so close.  Taking your suggestion re 2 amp secondary power supply, I
> will research and check with the local suppliers for same.  Earlier
> AlarmSaf  and Altronics (Australian?) were suggested so I will look for
> these in particular.
>
> Right now most of the expanders get their power from the loop extender
> which, in turn, gets its power via a DC transformer just as the panel
> does.  I gather I will be replacing the loop extender with the new (2
> amp) power supply.
>
> Thanks.
>
>
> Crash Gordon wrote:
> > Dood..heats don't draw anything neither does the waterflow switch.
> >
> > Is this that NY brownstone renovation discussed a while back?
> >
> > 15 smokes? Man!...I do 7-10000 sq ft houses that don't have that many in
> > them...anyway...
> >
> > adjusting for some of  your errors, you're probably really closer to 2.7 in
> > alarm without the sirens, but then again not everything will be in alarm.
> > I'd probably go 2 amp aux power...but remember some of this stuff you cannot
> > power off an aux power supply, like the smokes, the expanders, the keypads -
> > so you'll have to split your load between panel & secondary pwr supply...and
> > you'll need to common your gnds too.
> >
> > You really should have an alarm tech help you with this now that you have it
> > roughed-in.
> >
> > BTW...I rent myself out at 125 p/h...travel & food extra.