This are some copy's from the manuel NX4V2 Euro , as You can reed : no
extras are needed !

Zone Doubling

This feature allows you to use the four zones on the panel as eight normally
closed zones. When this feature is used, European double E.O.L.
configuration cannot be used. THIS FEATURE DOES NOT INCREASE THE TOTAL
NUMBER OF AVAILABLE ZONES BEYOND 8. If one of the eight zones must be a fire
zone, it must be one of Zones 1 to 4. The corresponding upper zone will
become unavailable. For example: if Zone 4 is a fire zone, then Zone 8 will
not be available. (See location 37, segment 5).

Location 37 segment 5 Location 2:   On: enables Zone Doubling (requires
NX-200 Zone Doubling Kit).

Greets

PS , Greece , its in Europe     ; ^ )






"Chub" <w@xxxxx> schreef in bericht
news:uFRAf.4491$SB2.2302@xxxxxxxxxxxxxxxxxxxxxxxxx
>
> "EJ" <Msecurity@be> wrote in message
> news:iNKdnck8eYuUQU7eRVnyhw@xxxxxxxxxxxxxx
>> ?? Not on that way with the NX4 panels I use !!
>>
>> Only with the  NX-200, Zone Doubling Kit (Includes  3.74k and  6.98k
>> resistors).
>
>
> must be different in europe than US.
> this is pasted from GE install manual NX4V2, [same for NX4]
> "Zone doubling can only be enabled when at least one other device is added
> to the basic system (consisting of the main control panel
>
> and one keypad). Additional devices can include wireless receivers, extra
> keypads, etc. If enabled, this feature allows you to use the
>
> four zones on the panel as eight normally closed zones. When this feature
> is used, European double E.O.L. configuration cannot be
>
> used.. THIS FEATURE DOES NOT INCREASE THE TOTAL NUMBER OF AVAILABLE ZONES
> BEYOND 8. If one of the eight
>
> zones must be a fire zone, it must be one of Zones 1 to 4. The
> corresponding upper zone will become unavailable. For example: if
>
> Zone 4 is a fire zone, then Zone 8 will not be available. (Loc 37, pg 17)"
>