Re: NX4



"EJ" <Msecurity@be> wrote in message
news:iNKdnck8eYuUQU7eRVnyhw@xxxxxxxxxxxxxx
> ?? Not on that way with the NX4 panels I use !!
>
> Only with the  NX-200, Zone Doubling Kit (Includes  3.74k and  6.98k
> resistors).


must be different in europe than US.
this is pasted from GE install manual NX4V2, [same for NX4]
"Zone doubling can only be enabled when at least one other device is added
to the basic system (consisting of the main control panel

and one keypad). Additional devices can include wireless receivers, extra
keypads, etc. If enabled, this feature allows you to use the

four zones on the panel as eight normally closed zones. When this feature is
used, European double E.O.L. configuration cannot be

used.. THIS FEATURE DOES NOT INCREASE THE TOTAL NUMBER OF AVAILABLE ZONES
BEYOND 8. If one of the eight

zones must be a fire zone, it must be one of Zones 1 to 4. The corresponding
upper zone will become unavailable. For example: if

Zone 4 is a fire zone, then Zone 8 will not be available. (Loc 37, pg 17)"

Zone Types (Configurations)