Re: Looking for a basic alarm system



"Crash Gordon" <webmaster@xxxxxxxxxxxxxxxxxxxxx> wrote in message
news:hc7Af.22$KW.1577@xxxxxxxxxxxxxxxxxx
> They were all take overs, so the struggle to program them didn't endear me
> to want to continue using the product. Maybe one day Napco will send me a
> evaluation panel for me to play with :-)
>
>

I have to say the P1632 is my main stream panel.  I never use the 3200
anymore.  I jump up to the 9600 if I need more zones or more programability.
They both have a nice menu programming feature for basic setup, and then 'by
address' programming for the detailed stuff, or just break out the laptop.

The P800/1 is my low end panel and it is very very easy to setup.

Those 4 zone Express panels never impressed me.  Kinda in the same class as
the DSC 550.  Sorry, that just trying to shave way too much off the cost of
an install.

--
Bob La Londe
http://www.YumaBassMan.com



> "Bob La Londe" <usenet@xxxxxxxxxxxxxxxxx> wrote in message
> news:aYydnSi2prjT_03eRVn-vA@xxxxxxxxxxxxxxx
> |
> | "Crash Gordon" <webmaster@xxxxxxxxxxxxxxxxxxxxx> wrote in message
> | news:SJUzf.66$8f.7900@xxxxxxxxxxxxxxxxxx
> | >I have a handful of Gemini 816s (?)...I cringe whenever I might have to
> | >make
> | > a programming change. I cant wait for them to get hit by lightning :-)
> |
> | I have not used any 816s as I always felt they were a brain damaged
> version
> | of the 1632 without enough savings to justify the reduced zones and
> | features.
> |
> | However, they are a pretty easy to program with a laptop as are the
> P1632s.
> | The 3200s and 9600s are onyl a little more difficult because they have
> some
> | many programming options.
> |
> |
> | --
> | --
> | Bob La Londe
> | http://www.YumaBassMan.com
> |
> |
> |
> | > "Bob La Londe" <usenet@xxxxxxxxxxxxxxxxx> wrote in message
> | > news:dfGdnZS5XZ9yiFLeRVn-qA@xxxxxxxxxxxxxxx
> | > |
> | > | "Crash Gordon" <webmaster@xxxxxxxxxxxxxxxxxxxxx> wrote in message
> | > | news:O6uzf.10$BE4.336@xxxxxxxxxxxxxxxxxx
> | > | > I've never been partial to Napco programming.
> | > | >
> | > |
> | > | The old MA panels were a pain, and in the newer Gemini series the
> 1632,
> | > | 3200, and 9600 are a not really easy to keypad program all the
> features,
> | > but
> | > | the P800 and P801 are the easiest panels I have ever programmed, and
> yes
> | > I
> | > | have programmed a frew Ademco panels.
> | > |
> | > | --
> | > | Bob La Londe
> | > | http://www.YumaBassMan.com
> | > |
> | > |
> | >
> | >
> |
> |
>
>




alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home