Re: Firelite Power problems (in general)



Firelite  in general,
I've notice that the charger ckt is always set right on the edge of fail
detection.
I reset the output level right out of the box to a slightly higher voltage.
(as recommended from a service tech from firelite, about 8 years ago)
to date (knock on wood) I haven't had any more problems with firelite power
supplies.
As for the dialers (whatever panel your using)  I've noticed a LOT of bad
solder connections
on the telephone line sockets..  I've had to resolder several to stop
intermittant line failure
signals.  (it seems if you send it back to firelite  they never see the
problem)
I've been using Firelite products for going on 18 years  with only the above
problems..
all in all  I like the product.  But thats just me..
RTS

"Mike Sokoly" <secure15@xxxxxxxxxxxxx> wrote in message
news:LTB8f.21103$ol.18026@xxxxxxxxxxx
> To add to the rant on Firelite:
> Had a 5024 installed by another Dealer about 4 years ago- then Nassau
> County Fire Marshal wants 24Hr test and Central Staion on a Residential
> Group Home! Obliged by Installing a 411 dialer. Alls well till beginning
> of last month- getting "Zone 2 Tbl- 1 sec on then a restore
> intermittently- "oh its the Dialer" "oh its the Phone Lines", this that
> and the other thing! After Tightening all connection, testing the DACT,
> replacing the Batteries, checking ALL Eol's, and connections I then
> start getting "Phone 1 Tbls" intermingled with the Phantom Zn 2 Tbl-
> After service call #3 - YES,---- There is crosstalk and hum on Phone 1
> AND Their FAx line is shorting with Panel Phone 1----BUT WAIT! As I am
> PHYSICALLY standing in front of the Panel and looking directly at it- I
> hear the sonalert beep twice and I WATCH the Panel TBL Light Blink
> on/off, on /off then Simultaneously the Panel "Power" TBL lite comes on
> with the Generic TBL lite, both blink twice then stop! Sounds to me from
> the thread that the Panel Power/Charging CKT is the Problem!!!!! Replace
> Main Board (not me- the original dealer) guess what- NO MORE PROBLEM.
> Which is why I INSIST ON INSTALLING SILENT KNIGHT!
> Mike S
>
>
>
> Bob La Londe wrote:
> > "Jackcsg" <nospam@xxxxxxxxxx> wrote in message
> > news:lqidnWkMRNonbPzeRVn-pw@xxxxxxxxxxxxxxx
> >
> >>Up in New England we referred to FireLite as "Fire Lightning".
> >>What you're stating is not uncommon.
> >>I've logged a few thousand hours replacing FireLite panels.
> >>At least they weren't the older Sensiscan 2000 panels...
> >>
> >
> >
> > I think FireLite may find itself not on my shopping list anymore.
> >
> >
> >
> >
> >>"Michael" <sirflannelNO@xxxxxxxxxxxxx> wrote in message
> >>news:94m2m1d83sdlnduer9lfjigj920kvd919k@xxxxxxxxxx
> >
> >
> >>>ALL were Firelite (one 5210, the rest 5024's).
> >
> >
> > Have you called or e-mailed Firelite, and what was their response.
> >
> > Did they soumd like they were trying to help or they were trying to
blame
> > problems on something else?
> >
> >
> >




alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home