[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Sentrol 5150



> My first question is, isn't it better to have put them in the upper
> right of the bottom and the lower right of the top, causing access to
> that top window's pull apart to be much more difficult.  If the bottom
> window is opened, all someone has to do is lower the top a little bit
> and jump the wires, if that is possible.

You should install a magnetic sensor (contact) to detect if someone opens
the window as well.

> Second question, the 5150 came with some kind of double sided tape
> that must have fallen out of the bag.  Was that just double sided tape
> or tape with some kind of metal to amplifly the sound or vibration of
> the breaking glass?

It's nothing special but you need to replace it with relatively thin tape.
I've seen some folks use carpet tape and it worked quite well.  The stuff
used to mount components inside the alarm control panel is too thick.  It
will dampen the vibrations and may prevent the sensor from functioning.

--

Regards,
Robert L Bass

=============================>
Bass Home Electronics
2291 Pine View Circle
Sarasota · Florida · 34231
877-722-8900 Sales & Tech Support
http://www.bassburglaralarms.com
=============================>