Re: casi rusco
Just so I know, what readers are you using? I guess they're not Casi, as
casi prox readers will supervise the door devices when using an 8RP so all
you need to run is a 2pr/22. Since your familiar with the software, you
probably know that already.
Andrew
"neil" <neilmiles@xxxxxxx> wrote in message
news:1124129836.148280.104940@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
> thanks Sam, the CK8RP is design for take over of Card Key access
> control system using the readers and twisted pair wire that runs from
> the Card Key controller to door modules. The CK8RP board has 8 reader
> ports and one 9 pin connector built on the board and this is for
> flashing the STI boards out in the field. In the Flashtool program
> under File theres a selection for flashing STI boards.The STI boards
> are similar to the WIU-4 boards used to connect HID readers to the 8RP
> boards thanks neil
>