[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: More Experiments With My Old Rittenhouse Smokes, & Interconnecting New Ones
Hi,
The volt I measure from the red wire to the black, with all the smokes
Dis-connected is about 2 to 4 volts AC. Should of course be 0, as the
assumption would be that the red is floating.
Bob
---------------------------------
"Crash Gordon®" <NONE@xxxxxxxx> wrote in message
news:np9be.28$pc.7703@xxxxxxxxxxxxxxxxxx
Whats the voltage on the black?
Maybe it's just wired weird somewhere.
"Robert11" <rgsrose@xxxxxxxxx> wrote in message
news:eoGdnabKKJ1CQPHfRVn-hA@xxxxxxxxxxxxxx
> Hi,
>
> Thanks guys for all the help.
> Really appreciate it.
>
> The wires and wiring looks original.
> The smokes look original, and are probably about where one would expect
> them
>
> The really funny thing, among others, is that when I put one of the old
> Rittenhouse
> units on the bench by itself, hooked up power to it, I measured 110 V AC
> from what I am calling the interconnect wire to neutral. This is for, of
> course, the untriggered state.
>
> I can't imagine how this thing was supposed to ever work !
>
> With 110 V on the wire all the time when not triggered, what happened when
> triggered; was it supposed to go to 0 V, or... ? A relay hidden
> somewhere
> ?
>
> Sure sounds like a weird way of doing things.
>
> Any possibility that what I think was an interconnect wire on the old
> units
> really was used for something else ?
>
> Thanks,
> Bob
> --------------
>
>
> "Crash Gordon®" <NONE@xxxxxxxx> wrote in message
> news:6DSae.9$4W5.2448@xxxxxxxxxxxxxxxxxx
> Does the 14/3 look original to the home? Are the locations where you
> expect
> to see smokes...or does it look like a slightly goofy retro fit?
>
>
> "Robert11" <rgsrose@xxxxxxxxx> wrote in message
> news:CMmdnfLlDfJMGfbfRVn-hA@xxxxxxxxxxxxxx
> > Hi,
> > Thanks for help. Appreciate it.
> >
> > Yes, normal 3 wire Romex 14/3 white, black, red, + Gnd
> >
> > Regards,
> > Bob
> > -----------------
> >
> > "Crash Gordon®" <NONE@xxxxxxxx> wrote in message
> > news:avJae.2$4W5.76@xxxxxxxxxxxxxxxxxx
> > And, what do you have between black & white?
> > I doubt there was a relay on a 110 VAC smoke.
> > And...are we talking about a Romex 14/3 (white, black, red + ground)?
> >
> >
> > "Robert11" <rgsrose@xxxxxxxxx> wrote in message
> > news:mN6dnXMpFY2trvXfRVn-uA@xxxxxxxxxxxxxx
> > > Hi,
> > >
> > > Thought I'd take a second and tell everyone my latest experiment with
> > > the
> > > old Rittenhouse wired-in smoke detectors that I removed, and replaced
> > > with
> > > the new Kidde PI 2000 ones, and my difficulties in interconnecting
> > > them.
> > > See my previous posts on this.
> > >
> > > As mentioned, the interconnect line, with No detectors on it, shows 2
> > > V
> > > AC.
> > >
> > > So, I thought that I might learn something about how they might have
> > > been
> > > hooked up with
> > > the Rittenhouser's by doing a little experiment.
> > >
> > > Took an old Rittenhouse and hooked it up on the bench by itself with
> > > 110
> > > V
> > > AC.
> > > Measured between the white neutral and its interconnect wire.
> > >
> > > Guess what: 110 V AC on it !
> > >
> > > So, for you experts, how might they have been hooked up to the
> > > existing
> > > interconnect
> > > wire originally ? Does this say that there must be a relay somewhere
> > > ?
> > >
> > > Can't imagine how it could have worked with 110 V on the interconnect
> > > lead
> > > in the normal,
> > > non-tripped state ?
> > >
> > > Any thoughts ?
> > > Bob
> > >
> > >
> > >
> >
> >
>
>
alt.security.alarms Main Index |
alt.security.alarms Thread Index |
alt.security.alarms Home |
Archives Home